A-PAK ALARM SYSTEMS
10-1494 "A-PAK" Alarm
• NEMA1enclosure(INDOORUSEONLY)
• Automaticalarmreset
• Hornisrated87decibelsat10'
• 9Vbatteryback-up(batterynotincluded)
• 15'alarm(12V)tetheredswitch
• 6'powercord
• Auxiliarydrycontacts(useP/N10-2614)
• UL/CSAlisted
© Copyright 2011 Zoeller Co. All rights reserved.
Productinformationpresented
herereectsconditionsattime
ofpublication.Consultfactory
regardingdiscrepanciesor
inconsistencies.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
visit our web site:
www.zoeller.com
10-0126 INDOOR / OUTDOOR Alarm System includessamefeaturesofour10-0623with:
• NEMA4Xthermoplasticenclosure(6"X4"X3")
• Hornisrated88decibelsat10'
• 5Aauxiliarydrycontacts
• ULListedtoCanadianstandardcULus
10-2616 Auto-Dialer System
TheAuto-Dialerisasinglechannelvoicedialerthatcanbeusedwith
anydevicethatcanprovideanormallyopen/closedcontact.Itcan
beprogrammedtostoreuptofournumberstodial,includingstandard
(voice)telephones,mostcellularphones,andpagers.Itwillprovidea
16secondpre-recordedmessage.
• Voice-Chiptechnology(NOTAPES)
• Recordyourownpersonalmessages
• Dialseachcontactnumberuptofourtimes
• Internal9Vbatteryback-up(BatteryNOTIncluded)
• Toneorpulsedialonly(NOTintendedfordigitalphonelines)
Model10-0623
R
L
U
R
Tested to UL Standard UL 508
& Certied to CSA Standard
C22.2 No. 205
Model10-0126
C
R
L
U
US LISTED
Models10-1494
R
L
U
R
Tested to UL Standard
UL 508
& Certied to CSA
Standard
C22.2 No. 205
Models10-2613
R
L
U
R
Tested to UL Standard
UL 508
& Certied to CSA
Standard
C22.2 No. 205
Model10-2616AutoDialer
The "A-Pak" Alarm system sounds a horn when a potentially threatening liquid level
condition occurs. The horn can be silenced, but the alarm light remains on until the
condition is remedied. Once the condition is cleared, the alarm will automatically reset.
A green "POWER ON" light indicates 120V primary power to the alarm. A low battery
chirp feature indicates when the battery should be replaced. A red "ALARM" light
indicates a high-level condition.
10-2613 "A-PAK" Alarm
Same standard features of our 10-1494 with:
• 15'alarm(12V)alarmreedswitch
• Auxiliarydrycontacts(useP/N10-2615)
10-0682 DELUXE Alarm System includessamefeaturesofour10-0623with:
• 20'alarm(12V)tetheredswitch
• 6'115Vpowercordwithwater-tightcordconnectors
10-0623 INDOOR / OUTDOOR Alarm System
• NEMA3Renclosure(6.5"X4.5"X3")
• Automaticalarmreset,hornsilenceswitchandalarmtestswitch
• Hornisrated85decibelsat10'
• Pre-mountedterminalblockwithconnectionsforpumpandoatswitch
• 15'alarm(12V)tetheredswitch
• Powerconnectionsareeldwired
• UL/CSAlisted
NOTE: It is always recommended to power
the alarm from a separate circuit than the
pump to avoid losing power to both during
a tripped breaker scenario.