Product Overview

© Copyright 2011 Zoeller Co. All rights reserved.
10-0028 Alarm System
Non-Enclosedmodel
Operateson115Vcircuit
3"magneticbellwithtransformer
Mountsonstandardutilitybox(NotIncluded)
15'alarm(12V)TetheredSwitch
Model10-0028
A-PAK ALARM SYSTEMS
ZOELLER
ALARM
ZOELLER
PUMP "ON"
PUMP "OFF"
FIBERGLASS
OR POLYETHYLENE
BASIN
"ON" LEVEL
VARIABLE LEVEL
CONTROL SWITCH
LEVEL
LEVEL
4" (10 cm) OF GRAVEL
ALARM
ZOELLER
TO POWER SUPPLY
TO POWER SUPPLY
UNICHECK
TEST
SILENCE
ALARM
POWER ON
DO NOT PLUG A-PAK ALARM SYSTEM
INTO THE SAME CIRCUIT AS THE PUMP.
NOTE:
SK2376
NOTE: All variable level oat switches in this
section are mechanically activated and do
not contain mercury.
High water alarms provide the owner with early
notication that the water level is continuing to
rise in the application. This could be due to a
pump failure or power outage, or the pump is
simply overwhelmed in the application.
Zoeller recommends that ALL systems be
installed with a high water alarm whether it is a
small sump pump, sewage system, or a large
outdoor lift station. Small alarms can be used
on systems like water heaters or drain sinks.
For a low upfront cost, a high water alarm
saves the headache and stress of cleaning up a
catastrophe after the fact.
An alarm system is designed to operate
independently from the pump; meaning it can be
used with any manufacturer's model. In fact, it
is recommended that all alarms are wired in to a
separate circuit breaker. This protects the alarm
from being tripped if the pump inadvertantly trips
the circuit breaker. The last thing a homeowner
wants is to NOT have an alarm due to the system
not getting power. For instances like a complete
power failure, most alarms include a 9V battery
back-up that keeps power to the alarm during a
storm or black-out.
10-0015 / 10-0016 Bell Alarm System
Non-Enclosedmodel
10-0015operateson115Vcircuit
10-0016operateson230Vcircuit
6"magneticbellwithtransformer
Mountsonstandardutilitybox(NotIncluded)
15'alarm(12V)TetheredSwitch
• Operateswith10-0743oatswitchormechanical
alternator-seeFM0495(NotIncluded)
Models10-0015&10-0016