Submittal Sheet

INSTALLATION
1.Unpackunitandinspectfordamage.
2.ReviewFigure1foratypicalinstallation.
3.Followinstructionsincludedwitheachpumpforproperpumpinstallation.
Testpumponandoffcycleseveraltimestoensureproperpumpcycling.
4.Mountunitonwallwithinreachofpumps’cords.
5.Mountthealarmswitchononeofthedischargepipesacoupleinchesabove
theonlevelofthepumps.Ifpossible,thisshouldbebelowtheinlettothepit.
6.ConnectthealarmoatswitchcordtotheHighWaterconnectionontheside
oftheSmart-PakPlus.
7.Plugthepowercordintoaproperlygroundedoutlet.
8.Checksystemforproperoperationasoutlinedbelow.
Allinstallationsmustbeinaccordancewiththe
NationalElectricCode,andanyotherapplicablestateandlocal
electricalrequirements.
Do not remove ground pin. Severeelectrical
shockcouldoccur.
NORMAL OPERATION
UponrstpluggingtheSmart-PakPlusintoACpower,thefourLEDlightswill
illuminatebrieyinred,thengreen.TheLEDlightswillturnoff,thenthePump1
andPowerLEDlightswillilluminategreen.Whenwaterrisestothelevelthatboth
pumps’switchesareon,theunitwillsendpowertoPump1untilitsswitchturnsoff.
ThePump2LEDwillthenilluminateindicatingthatpowerwillbeprovidedtoPump
2oncebothpumps’switchesareonceagainon.Thecontrolunitwillcontinueto
alternatebetweenpumps1and2,inthismanner,untilanalarmisdetected.The
PowerLEDremainsgreenaslongasACpowerisavailable.
© Copyright 2013 Zoeller Co. All rights reserved.
ALARM OPERATION
Therearevemodesofalarmoperation,asfollows:
1. High Water Alarm Operation
Ifthesump’swaterlevelreachesthelevelofthehigh-wateroatswitch,thealarm
willsound,drycontactswillcloseandtheunitwillautomaticallyalternatepowerto
theotherpump.Oncethewaterleveldropsbelowtheofflevelofthehigh-water
oatswitch,thealarmwillcontinuetosoundandthelightwillashred.Pressing
theSilence/Resetbuttononthefrontoftheunitwillquietthealarmandleavethe
LEDilluminated.Oncethealarmeventhasended,pressingtheSilence/Reset
buttonforvesecondsorlongerwillresetthealarmandthelightwillnolonger
beilluminated.Ifpowerisoutandahigh-waterconditionispresent,thePower
LEDashesredandthealarmchirpseverythreeseconds.(Thepumpwillnot
runwhileunitisonbatterypower.)
2. Loss of Power Alarm Operation
IfACpowerislost,thealarmandLEDlightsoperateuntilinternalbatteryisdead
orACpowerisrestored.ThePowerLEDashesredandalarmchirpsevery12
seconds,andthedrycontactsclose.TheredLEDandalarmwillclearthemselves
ifpowerisrestored.
3. Continuous Pump Run Alarm Operation
Ifeitherpumprunscontinuousforover300seconds,theSmart-PakPluswill
alternatetotheotherpump,theLEDforthepumpashesred,theaudiblealarm
willsound,anddrycontactsclose.TheredLEDandalarmwillclearthemselves
iftheconditionisremedied.Afterveconsecutivefaults,thealarmwillremain
onuntilitismanuallyreset.
4. Breaker Tripped Alarm Operation
Ifthe activepump drawsmore than14 ampscontinuously thealternatorwill
switchtotheotherpump.Afterveconsecutivecycleswhereapumpdrawsmore
than14amps,thealternatorwilldisablethatpump.Iftheactivepumphasan
instantaneouscurrentdrawofmorethan30ampsfortwoconsecutivecyclesthe
alternatordisablesthepump.EitherconditionwillcausetheredLEDtoashfor
thefailedpump,soundthealarm,andthedrycontactsclose.TheSmart-Pak
Pluswillnotattempttousetheproblematicpumpagainuntilthealarmisreset.
5. Pump Failure Alarm Operation
Ifthe Smart-Pak Plusdetectsthat oneofthe pumpsdoesnot run,afterve
consecutivecyclesofthehigh-wateralarmtripping,thatpump’sLEDashes
red,thealarmsoundsandthedrycontactsclose.
SILENCE/RESET BUTTON
PressingtheSilence/Resetbuttonsilencestheaudiblealarm.Additionalalarm
conditionswillsoundthealarmagain.PressingandholdingtheSilence/Reset
buttonforvesecondswillresetanyfaults.
BATTERY
TheSmart-PakPlushasarechargeablenickel-metal-hydridebatteryinstalled
intheunit.Thechargingcircuit“exercises”thebatterytoextendthelifeofthe
batteryandreducepowerconsumption.Batteryisnotreplaceableintheeld.
NOTES:
• Useofaworkinghigh-wateralarmswitch,properlyconnectedtotheSmart-PakPlus,isrequiredinordertoallowforemergencypumpalternation.
• TheSmart-PakPlusdoesnotprovidepowertoACpumpsduringapowerloss.
• Almostanystandard,normallyopenpumpswitchcanbesubstitutedfortheincludedhigh-wateralarmoatswitch.
•TheSmart-PakPluswillnotoperatethepumpsatthesametime.
• TheSmart-PakPlusisapumpalternatingdevice.Itisnotintendedtobypassoraugmentthepumps’switches.Workingswitchesarerequiredforproper
pumpoperation.
Branch circuit
should be protected as per the
National Electrical Code.
Sk2954
PUMP 1
PUMP 2
POWER
HIGH WATER
ALARM
P/N 152447-A
R
R
RESIDENTIAL ALTERNATOR
SILENCE/RESET
12 AMP MAX.
115V AC
SMART PAK PLUS
PUMP 2
PUMP 1
(ENLARGED FOR CLARITY)
ALTERNATOR PANEL
Figure 1: Typical Installation