Installation Sheet
4
If the above checklist does not uncover the problem, consult the factory. Do not attempt to service or otherwise disassemble pump. Service must be
performed by Zoeller Authorized Service Stations. Go to www.zoellerpumps.com/servicestations to nd the Authorized Service Station in your area.
CONDITION
A. Pump will not start or run.
B. Motor overheats and trips overload or blows.
C. Pump starts and stops too often.
COMMON CAUSES
Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal
bound mechanically, defective capacitor or relay when used, motor or wiring shorted. Float
assembly held down. Switch defective, damaged, or out of adjustment.
Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound
mechanically, defective capacitor or relay, motor shorted.
Float tight on rod, check valve stuck or none installed in long distance line, overload open,
level switch(s) defective, sump pit too small.
Debris under oat assembly, oat or oat rod bound by pit sides or other, switch defective,
damaged or out of adjustment.
Check strainer housing, discharge pipe, or if check valve is used vent hole must be open.
Discharge head exceeds pump capacity. Low or incorrect voltage. Incorrect motor rotation.
Capacitor defective. Incoming water containing air or causing air to enter pump.
Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemi-
cals could possibly deteriorate impeller and pump housing. Check line. Remove base and
inspect.
D. Pump will not shut off.
E. Pump operates but delivers little or no water.
F. Drop in head and/or capacity after a period of use.
SERVICE CHECKLIST
ELECTRICAL PRECAUTIONS - Before servicing a pump, always shut off the main power breaker and then unplug the pump - making sure you are wearing
insulated protective sole shoes and not standing in water. Under ooded conditions, contact your local electric company or a qualied licensed electrician for disconnecting
electrical service prior to pump removal.
Submersible pumps contain oils which becomes pressurized and hot under operating conditions. Allow 2½ hours after disconnecting before attempting ser
vice.
009789A
009789B
0
10 20 30 40 50 60 70 80 90 100 110 120
0
5
10
15
20
25
30
35
40
45
50
55
65
LITERS
GALLONS
FEET
METERS
40 80 120 160 200 240 280 320 360 400 440
2
4
6
8
10
12
14
16
18
PUMP PERFORMANCE CURVE
MODELS 3098-3137-3139-3161-3163-3282
200° F (93° C) WATER TEMPERATURE
3163 3098 3137/
3139
3161 3282
FLOW PER MINUTE
TOTAL DYNAMIC HEAD
60
Feet
MODEL
Shut-off Head:
Meters LitersGal. Gal. Liters Gal. Liters Gal. Liters Gal. Liters
3098 3137/3139 3161
3163
3282
5 1.5
10
15
20
25
30
40
50
4.6
15.2
12.2
9.1
7.6
6.1
3.0
21 ft.(6.4m) 25 ft.(7.6m) 51 ft.(15.5m) 60 ft.(18.3m) 24 ft.(7.3m)
41 155
23 87
66
56
250
212
20153
30 114
90
75
341
284
34892
84 318
106
100
401
378
41 155
308
246
28074
65
19351
189
182
170
132
20
35
76
45
48
50
201
197
53
52
20855
25 95
115
85
435
322
-- -- -- --
--
--
----
--
----
--
----
--
--
-- --
--
--
----
--
--
© Copyright 2015 Zoeller
®
Co. All rights reserved.