Spec Sheet

© Copyright 2017 Zoeller
®
Co. All rights reserved.
502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | www.zoeller.com
012116
0 200
50 100 150 200 250
800600400 1000 1200 1400
350300 400
0
5
2
4
6
8
25
20
15
10
40
35
30
10
12
LITERS
GALLONS
METERS
FEET
FLOW PER MINUTE
TOTAL DYNAMIC HEAD
PUMP PERFORMANCE CURVE
MODELS 404/4404/405/4405
3" SOLIDS CAPACITY
404/4404
405/4405
TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
SEWAGE AND DEWATERING
MODEL
Feet
Shut-off Head:
404/4404 405/4405
Meters Gal. Liters Gal. Liters
136736111363001.55
1234326
284 1075848
1003265
2244.6
3.010
15
912241
197 746503
698184
1347.6
6.120
25
507134
50 189--
22760
--10.7
9.130
35
33 ft.(10.1m) 38 ft.(11.6m)
*CSA approved, all other models are UL and cCSAus approved.
Additional cord lengths are available in 25' (8 m), 35' (11 m) and 50' (15 m).
Model
MODEL COMPARISON
Seal Mode Volts Ph Amps HP Hz Lbs Kg Simplex Duplex
E404 Single Non 230 1 12.9 2 60 136 61 1 or 2 3
E4404 Double Non 230 1 12.9 2 60 147 66 1 or 2 3
WD404 Single Auto 230 1 12.9 2 60 139 63 ** ---
WD4404 Double Auto 230 1 12.9 2 60 150 68 ** ---
I404 Single Non 200 1 14.4 2 60 136 61 2 3
I4404 Double Non 200 1 14.4 2 60 147 66 2 3
J404 Single Non 200 3 13.8 2 60 136 61 2 3
J4404 Double Non 200 3 13.8 2 60 147 66 2 3
F404 Single Non 230 3 10.5 2 60 136 61 2 3
F4404 Double Non 230 3 10.5 2 60 147 66 2 3
G404 Single Non 460 3 5.2 2 60 136 61 2 3
G4404 Double Non 460 3 5.2 2 60 147 66 2 3
BA404 Single Non 575 3 4.1 2 60 136 61 2 3
BA4404 Double Non 575 3 4.1 2 60 147 66 2 3
*E405 Single Non 230 1 19.0 3 60 136 61 1 or 2 3
*E4405 Double Non 230 1 19.0 3 60 136 61 1 or 2 3
*WD405 Single Auto 230 1 19.0 3 60 139 63 ** ---
*WD4405 Double Auto 230 1 19.0 3 60 150 68 ** ---
I405 Single Non 200 1 20.2 3 60 136 61 2 3
I4405 Double Non 200 1 20.2 3 60 145 65 2 3
J405 Single Non 200 3 14.8 3 60 136 61 2 3
J4405 Double Non 200 3 14.8 3 60 147 66 2 3
F405 Single Non 230 3 12.2 3 60 136 61 2 3
F4405 Double Non 230 3 12.2 3 60 147 66 2 3
G405 Single Non 460 3 6.1 3 60 136 61 2 3
G4405 Double Non 460 3 6.1 3 60 147 66 2 3
BA405 Single Non 575 3 4.1 3 60 136 61 2 3
BA4405 Double Non 575 3 4.1 3 60 147 66 2 3
SELECTION GUIDE
1. For automatic use single piggyback variable level float switch or
double piggyback variable level float switch. Refer to FM0477.
2. See FM1228 for correct model of simplex control panel.
3. See FM0712 for correct model of duplex control panel.
All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be
followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).
CAUTION
TOTAL DYNAMIC HEAD FLOW PER MINUTE