Installation Instructions
3
TheDCcontrollerisequippedwithachargerformaintainingthebattery
inareadystateandrechargingthebatteryafterusewhenACpoweris
restored.Timeforrechargedependsupontheamountofpowerconsumed
bythepumpingcycleduringtheACpowerinterruption.Thepumpmaygo
backtothereadyrunpositioninaveryshortperiodoftime.Acompletely
drained battery may require up to 24 hours for full recharge. If battery does
notchargeproperly,theLEDbatterywillashred.
PERFORMANCE
TheDCpumpperformanceat12.7Vdc
BATTERY SELECTION
Discharge
Feet of Head
5
(1.5 m)
10
(3 m)
15
(4.6 m)
28
(85 m)
Flow
GPM (LPM)12.7 volts
43
(163)
35
(132)
27
(102)
Shut-off
Head
Thissystemisabackuptoyourprimarysumppump.Itisdesignedtoprovideoodpreventionduringpoweroutagesorprimarypumpfailure.Thissystemis
unique in that it has self-testing and communication features (if using with Gateway and Z Control
®
Cloud).
DESCRIPTION
SK3183
TheDCemergencypumpsystemrequiresagoodquality,12voltbattery
toobtainmaximumpumpingtimeduringapoweroutage.Adeep-cycle,
12 volt, 105 amp-hour marine battery or larger is recommended and will
provide approximately 5.5 hours of continuous pumping time in a sump
pumpinstallationwith8'(2.4m)ofheadpressure.Inmostinstallations,
the pump runs intermittently and the battery life is extended accordingly.
Batteries with top terminals are recommended for ease of installation.
"Wet" cell batteries contain acid, and proper precaution must be taken
when handling. Battery box will accommodate a maximum battery size
of13-1/2"(34.3cm)Lengthx7"(17.8cm)Widthx9-1/2"(24.1cm)Height.
AGMbatteriesalsorecommended.Donotusegelbatteriesorautomotive
batteries.
Pump
Construction Non-corrodible plastic, premium seals
Performance 35GPMat10'(113LPMat3m)at12.7volts
ContinuousRunningTime 5.5 hours
Duty Cycle of 10% 2 days
Connection 9'(2.7m)wirewith2positionconnector
Controller
Construction ABSplastic
Power Requirement 115 V 15 amp circuit
Consumption Up to 3 amps at 115 V
Charger output 7 amp multi-stage
Connections
8'(2.4m)ACpowercord,6'(1.8m)DCchargingcable,connectionsforpump,operationswitch,highwaterswitch
Z Control
WiFi Built in
Battery
Box
Construction Non-corrodible plastic
Safety Snaptightlid,keepsbatterysafeandclean
*WhenACpowerisavailable,DCPumpoperationdoesnotdepletebattery.
© Copyright 2019 Zoeller
®
Co. All rights reserved.
2
3
1
4
5
12
10
11
9
6
7
8
12 VOLT BATTERY
SUPPLIED BY USER
Model 508 Fit
Item Description Qty
508-C
8/18
thru Current
1
Pump12VDC/Backup
(service part)
1 155652
2
Flapper asm, (service
part)
1 152970
3
Fitting, asm & clamp
"508" (service part)
1 152969
4
Fitting,PVC1-1/2"
(DN40)tee/SCH40
(pressuretting)
1 153766
5
Valve,check/1.5"
(DN40)Inline/vertical
1 153772
6 Operationaloat 1 155654
7
Clamp,#28Worm-SS
(oatswitch)
2 004287
8 Fit controller 1 155368
9
Fuse, 30 amp automo-
tive
1 016918
10 Highwateroat,NC 1 155653
11
Battery box asm (box
and cover)
1 10-0764
12
Hardware pak, charger
/switchmode
2 152864