Installation Instructions

6
AQUANOT
®
FIT FLOAT SWITCH
FIGURE 3
SK3186
FIT CONTROLLER FUNCTIONS
Therearetwobuttonsonthefrontofthecontroller.
- Silence/Reset
Can be pressed to silence current alarms for 24 hours.
Canbeheldforlongerthan3secondstoresetalarm.Resetwillclearashinglightonunit.
- Test
Will run the pump to determine if amp draw of pump is in range.
Controller is factory programmed to self-test the pump for several seconds every 24 hours.
Pressing the test button will start the 24-hour timer for self-testing.
AQUANOT FIT
Solid Flashing Off
System Ready No Faults (Green)
ACoffwithnofaults
(Green)
--
Battery
Charged (Green)
Low Battery (Red) NoACPowerCharging (Yellow)
Bad Battery (Red)
DC pump Pump Ran (Yellow)
Pump Running (Yellow)
--
Pump Fault (Red)
Float Status High Water (Red) Float Fault (Red) --
Z Control Connected Searching BroadcastingSSIDorDormant
TheLEDswilldisplayinformationaboutthecontroller.
© Copyright 2019 Zoeller
®
Co. All rights reserved.
LOCKING PIN MUST BE
INSTALLED UNDER FLOAT
ROD IN THIS LOCATION.
MOLEX 4-PIN CONNECTOR
MOLEX 2-PIN CONNECTOR
DC PUMP
DISCHARGE TEE
REDUCER FITTING
CLAMP
CHECK VALVE ASSEMBLY
CLAMP
SK2962
FIGURE 4