Spec Sheet
© Copyright 2019 Zoeller
®
Co. All rights reserved.
502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | zoellerpumps.com
016532
Model
MODEL COMPARISON
Volts Ph Amps Lbs Kg
E840 230 1 17.2 137 62
I840 200 1 20.0 137 62
F840 230 3 10.8 132 60
J840 200 3 12.3 132 60
G840 460 3 5.5 132 60
BA840 575 3 4.5 132 60
I841 200 1 20.0 137 61
E841 230 1 17.2 137 61
J841 200 3 12.3 132 61
F841 230 3 10.8 132 61
G841 460 3 5.5 132 61
BA841 575 3 4.5 132 61
I842 200 1 20.0 137 61
E842 230 1 17.2 137 61
J842 200 3 12.3 132 61
F842 230 3 10.8 132 61
G842 460 3 5.5 132 61
BA842 575 3 4.5 132 61
HEAD CAPACITY CURVE
MODEL 840/841/842
0 40 80 120 160 200 240
70605040302010
0
10
4
8
12
16
20
130
70
60
50
40
30
20
FLOW PER MINUTE
GALLONS
LITERS
TOTAL DYNAMIC HEAD
80
90
28
24
METERS
FEET
100
110
120
32
36
840 841842
TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
SEWAGE
MODEL
Feet
Shut-off Head:
840
Meters Gal. Liters
5
10
20
30 9.1
6.1
3.0
1.5
44
45
167
170
104 ft (31.7 m)
60
50
40
90
80
70
110
100
120
12.2
15.2
18.3
21.3
24.4
27.4
30.5
33.5
36.6
42
36
30 114
136
159
23
16
10 38
61
87
3
--
-- --
--
11
125 ft (38.1 m)
841
Gal. Liters
45 170
45 170
125 ft (38.1 m)
9525
13
4
20 76
49
15
34
32
29
34
34
34
34
129
121
110
129
129
129
129
842
Gal.
34
34
129
129
Liters
52
49 185
197
43
36
28 106
136
163
19
11
4 15
42
72
54 204
54 204
54 204
54 204
54 204
NOTE: All models are double seal, nonautomatic, 2 HP, and 60 Hz.
• Action can be manual or automatic.
• Panel required for automatic reversing action, thermal sensors and moisture probes.
All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be
followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).
CAUTION
Model 841 and 842 Electrical Data and Control Panel Selections
Models Weight Volts Phase HP Amps *Start Pak
**NEMA 4X Control Panels
Simplex Duplex
I841 137 lb's (62.1 Kg) 200 1 2 20.0 10-0380 10-1650 10-1652
E841 137 lb's (62.1 Kg) 230 1 2 17.2 10-0380 10-1650 10-1652
J841 132 lb's (59.8 Kg) 200 3 2 12.3 Not Required 10-1097 10-1125
F841 132 lb's (59.8 Kg) 230 3 2 10.8 Not Required 10-1097 10-1125
G841 132 lb's (59.8 Kg) 460 3 2 5.5 Not Required 10-1094 10-1122
BA841 132 lb's (59.8 Kg) 575 3 2 4.5 Not Required 10-1146 10-1168
I842 137 lb's (62.1 Kg) 200 1 2 20.0 10-0380 10-1650 10-1652
E842 137 lb's (62.1 Kg) 230 1 2 17.2 10-0380 10-1650 10-1652
J842 132 lb's (59.8 Kg) 200 3 2 12.3 Not Required 10-1097 10-1125
F842 132 lb's (59.8 Kg) 230 3 2 10.8 Not Required 10-1097 10-1125
G842 132 lb's (59.8 Kg) 460 3 2 5.5 Not Required 10-1094 10-1122
BA842 132 lb's (59.8 Kg) 575 3 2 4.5 Not Required 10-1146 10-1168
** Control Panels include Seal Leak Indication, Visual and Audible High Water Alarm and Dry Contacts. Single Phase Control Panels include Capacitors and Start
Relay.
TOTAL DYNAMIC HEAD
FLOW PER MINUTE