A-Pak Alarm Systems
ACCESSORIES AND CONTROLS
10-1494
10-0623 Indoor/Outdoor
10-0028 Alarm System
10-2613
10-0682 Deluxe
10-0126 Indoor/Outdoor
10-0015 / 10-0016 Bell Alarm

• NEMA1enclosure(INDOORUSEONLY)
• Automaticalarmreset
• Hornisrated87decibelsat10’(3m)
• 9Vbatteryback-up(batterynotincluded)
• 15’(5m)alarm(12V)tetheredswitch
• 6’(2m)powercord
• Auxiliarydrycontacts(use10-2614)

• NEMA3Renclosure(6.5”x4.5”x3”)
(16.5x11.4x7.6cm)
• Top-mountedalarmbeacon
• Automaticalarmreset,hornsilence
switch and alarm test switch
• Hornisrated85decibelsat10’(3m)
• Pre-mountedterminalblockwithconnectionsforpump
and float switch
• 15’(5m)alarm(12V)tetheredswitch
• Powerconnectionsareeld-wired

• Non-enclosed model
• Operateson115Vcircuit
• 3”magneticbellwithtransformer
• Mountsonstandardutilitybox
(notincluded)
• 15’(5m)alarm(12V)tetheredswitch

Samestandardfeaturesofour10-1494with:
• 15’(5m)alarm(12V)alarmreedswitch
• Auxiliarydrycontacts(use10-2615)

Samestandardfeaturesofour10-0623with:
• 20’(6m)alarm(12V)tetheredswitch
• 6’(2m),115Vpowercordwith
water-tight cord connectors

Samestandardfeaturesofour10-0623with:
• NEMA4Xthermoplasticenclosure(6”x4”x3”)
(15.2x10.2x7.6cm)
• Hornisrated88decibelsat10’(3m)
• 5Aauxiliarydrycontacts

• Non-enclosedmodel
• 10-0015operateson115Vcircuit
10-0016operateson230Vcircuit
• 6”magneticbellwithtransformer
• Mountsonstandardutilitybox(notincluded)
• 15’(5m)alarm(12V)TetheredSwitch
• Operateswith10-0743oatswitchormechanicalalternator-
seeFM0495(notincluded)
The A-Pak” alarm system sounds a horn when a potentially threatening
liquid level condition occurs. The horn can be silenced, but the alarm
light remains on until the condition is remedied. Once the condition is cleared,
the alarm will automatically reset.
Agreen“POWER ON”lightindicates120Vprimary powertothealarm.Alowbatterychirp
featureindicateswhenthebatteryshouldbereplaced.Ared“ALARM”lightindicatesahigh-
level condition.
R
L
U
R
Tested to UL Standard
UL 508
& Certied to CSA
Standard
C22.2 No. 205
R
L
U
R
Tested to UL Standard
UL 508
& Certied to CSA
Standard
C22.2 No. 205
C
R
L
U
US LISTED
NOTE: All variable level oat switches in this section are
mechanically activated and do not contain mercury.
NOTE:Itisalwaysrecommendedtopowerthealarmfromaseparatecircuitthanthepumptoavoidlosingpowerto
both during a tripped breaker scenario.