• 115-208-230Volts
• Cleardeadfrontpanel
(10-0125only)
• Completewith(3)20’(6m)
control float switches
• Equipmentdisconnect
(10-0125only)
• Motorcontactor(allmodelsexcept10-1019and10-1023)
• NEMA4Xwatertightenclosurewithlockablelatch
• Top-mountedalarmlight
• Alarmhornprovidesaudiowarningofalarmcondition
(83to85decibelrating)
• Pumprunindicatorlight
• Hornsilenceandalarmtesttoggleswitches
• HOAswitch
• Dryauxiliarycontact(notavailableinplug-inpanels)

• 208-230-460-575Volts
• NEMA4X-watertightenclosurewithlockablelatch
• Hand-off-autotoggleswitch
• Greenpumprunlight
• Alarmtest&silenceswitches
• Redalarmbeaconandaudiblealarmforahighwater
condition(83to85decibelrating)
• Motorprotectionswitchwithoverloadprotection
• Magneticstarter
• Numberedterminalstripforconnectingpumpsand
variable level float switches
• Dryauxiliarycontactsforremotealarmdevices
• Threeoatoperation(oatsnotincluded-seeFM0526)
• Off-the-shelfcomponentsprovideeasyeldmaintenance
and repair

• 115V(10-1019)or230V(10-1023)
• NEMA4Xenclosurewith
hinged cover
• Receptacleforusewithpiggyback
pump switch
• Alarmhorn(83to85decibelrating)
• Terminalstrip
• Hornsilenceswitchtoturnalarmonoroff
• Alarmoatonly
Single Phase Control Panel
Three Phase
Plug-in Control Panel
Single Phase
ACCESSORIES AND CONTROLS
An Electrical ControlPanel is used on a Simplex pumpapplication where automaticelectrical cycling of the pump is
desired for added protection in residential or commercial applications. A Control Panel is required for all systems using a
nonautomatic pump. The built-in alarm system, a standard feature, will activate when the water level becomes unusually
high.AllelectricalsystemsmustbeinstalledbyaqualiedelectricianandaccordingtotheNationalElectricalCode(see
Section430-71though430-113,plusanyothersthatapply).
Electrical Simplex Control Panels

Model # Volts
DimensionsHxWxD
in(cm)
Amp
Range
Float switches included Features
10-1019 11 5 V 8”x6”x4”(20x15x10cm) 0-15 Alarm float only Plug-In
10-1023 230V 8”x6”x4”(20x15x10cm) 0-15 Alarm float only Plug-In
10-1036 115V,208-230V 8”x6”x4”(20x15x10cm) 0-7 Three20’(6m)controloats Circuit breaker disconnect
10-1037 115V,208-230V 8”x6”x4”(20x15x10cm) 7-15 Three20’(6m)controloats Circuit breaker disconnect
10-1038 115V,208-230V 8”x6”x4”(20x15x10cm) 15-20 Three20’(6m)controloats Circuit breaker disconnect
10-0125* 115V,208-230V 10”x8”x4”(25x20x10cm) 0-20 Three20’(6m)controloats Pull out disconnect
* 10-0125 Branch Circuit Protection provided by the installing electrician.

Model DimensionsHxWxD
in(cm)
Volts AmpRange
10-1074 12”x10”x6”(30x25x15cm) 208/230/460 1.0-1.6
10-1076 12”x10”x6”(30x25x15cm) 208/230/460 1.6-2.5
10-1078 12”x10”x6”(30x25x15cm) 208/230/460 2.5-4.0
10-1080 12”x10”x6”(30x25x15cm) 208/230/460 4.0-6.3
10-1082 12”x10”x6”(30x25x15cm) 208/230/460 6.0-10.0
10-1083 12”x10”x6”(30x25x15cm) 208/230/460 9.0-14.0
10-1084 12”x10”x6”(30x25x15cm) 208/230/460 13.0-18.0
10-1086 12”x10”x6”(30x25x15cm) 208/230/460 17.0 - 23.0
10-1132 12”x10”x6”(30x25x15cm) 575 1.6-2.5
10-1134 12”x10”x6”(30x25x15cm) 575 2.5-4.0
10-1136 12”x10”x6”(30x25x15cm) 575 4.0-6.3
C
R
L
U
US LISTED
C
R
L
U
US LISTED