• Hand-off-autotoggleswitchforeachpump
• Greenpumprunpilotlightforeachpump
• Alarmtestandsilenceswitches
• Redpilotlight(NEMA1only)andaudible
alarmwith83to85decibelratingforahigh-
water condition
• RedalarmbeaconincludedwithNEMA4x
enclosure
• Auxiliarydrycontact
• Highwateralarm
• Singlephase-circuitbreakerfor
each pump
• Threephase-motorprotectiveswitch
with overload protection
• Magneticstarterforeachpump
• Alternatingmechanism
•
Numbered terminal strip for connecting
pumps and variable level float switches
• NEMA1-generalpurposeor
NEMA4x-watertightenclosuresavailable
• Integralauxiliaryterminalboardconnections
(drycontact)forremotealarmdevices
• 3or4variableleveloatswitchcontrol
operation
• Three20’(6m)oatswitchesincluded
with single phase panels
• Off-the-shelfcomponentsprovideeasyeld
maintenance and repair
• Floatswitchesnotincludedwiththreephase
panels
For Duplex Installations
ACCESSORIES AND CONTROLS
An ElectricalAlternator is used on a Duplex pump application where
automatic alternation of the pumps is desired for added protection in
residential or commercial applications. With one pump operating to
handle normal flow, a second pump becomes operational in the event
the water level continues to rise. The built-in alarm system, a standard
feature, can be connected to sound either when the second pump becomes
operationalwitha3-oatswitchsystemorindependentlywitha4-oat
switch system. All electrical systems must be installed by a qualified
electrician and according tothe National Electrical Code.(see Section
430-71though430-113,plusanyothersthatapply).
Electrical Alternator Control Panel
NOTE: 600 and X600
Series single phase pumps
require special panels that
include start components. See
SelectionGuideFM1228and
FM1705 for correct panel
selection.
NOTE:Allvariableleveloat
switches in this section are
mechanically activated and
do not contain mercury.


Order No. DimensionsHxWxDin(cm) Volts AmpRange
10-1039 12”x10”x6”(30x25x15cm) 11 5 7-15
10-1040 12”x10”x6”(30x25x15cm) 11 5 15-20
10-0092* 12”x10”x6”(30x25x15cm) 115/200/230 0-20

10-1041 12”x10”x6”(30x25x15cm) 11 5 7-15
10-1042 12”x10”x6”(30x25x15cm) 11 5 15-20
10-1043 12”x10”x6”(30x25x15cm) 115/200/230 0-7
10-1044 12”x10”x6”(30x25x15cm) 115/200/230 7-15
10-1045 12”x10”x6”(30x25x15cm) 115/200/230 15-20
10-1046 12”x10”x6”(30x25x15cm) 115/200/230 20-30
10-0093* 12”x10”x6”(30x25x15cm) 115/200/230 0-20
*Branch circuit protection provided by installing electrician.


Order No. DimensionsHxWxDin(cm) Volts* AmpRange
10-1102 14”x12”x6”(36x30x15cm) 200/230/460 1.0-1.6
10-1104 14”x12”x6”(36x30x15cm) 200/230/460 1.6-2.5
10-1106 14”x12”x6”(36x30x15cm) 200/230/460 2.5-4.0
10-1108 14”x12”x6”(36x30x15cm) 200/230/460 4.0-6.3
10 - 1110 14”x12”x6”(36x30x15cm) 200/230/460 6.3-10.0
10 - 1111 14”x12”x6”(36x30x15cm) 200/230/460 9.0-14.0
10 - 111 2 14”x12”x6”(36x30x15cm) 200/230/460 13.0-18.0
10 - 1114 14”x12”x6”(36x30x15cm) 200/230/460 17.0-23.0
10 - 111 5 14”x12”x6”(36x30x15cm) 200/230/460 20.0-25.0
10-1183 14”x12”x6”(36x30x15cm) 200/208 23.0-32.0
10-1154 14”x12”x6”(36x30x15cm) 575 1.6-2.5
10-1156 14”x12”x6”(36x30x15cm) 575 2.5-4.0
10-1158 14”x12”x6”(36x30x15cm) 575 4.0-6.3
*Three phase panel has multi-tap transformer with secondary fusing.