Spec Sheet

SELECTION GUIDE
1. Integral oat operated mechanical switch, no external control required.
2. For automatic use single piggyback variable level oat switch or double piggyback
variable level oat switch. Refer to FM0477.
3. See FM1228 for correct model of simplex control panel.
4. See FM0712 for correct model of duplex control panel or FM1663 for a residential
alternator system.
Three phase pumps are available in 200/208V, 230V or 460V.
Electrical alternators, for duplex systems, are available and supplied with an alarm.
Mechanical alternators, for duplex systems, are available with or without alarm switches.
Simplex Panels are available for 3 phase pumps.
Control alarm systems are available for 1 phase pumps.
Variable level control switches are available for controlling single and 3 phase systems.
Double piggyback variable level oat switches are available for variable level long
cycle controls.
Over 130°F (54°C) special quotation required.
Refer to FM1922 and FM0806 for temperatures over 130°F (54°C).
CONSULT FACTORY FOR SPECIAL APPLICATIONS
© Copyright 2014 Zoeller
®
Co. All rights reserved.
1 1/2 NPT
4 13/16"
4 13/16" [12.2cm]
7 7/16"
6 1/8"
12 3/4" [32.4cm]
3 15/16' [10.0cm]
[15.6cm]
[18.9cm]
[12.2cm]
SK373
009921
*No molded plug **Single piggyback switch included.
Pumps must be operated in upright position.
Three phase units require a control switch to operate an external magnetic contactor.
For information on additional Zoeller products refer to catalog on Piggyback Variable
Level Float Switches, FM0477; Electrical Alternator, FM0486; Mechanical Alternator,
FM0495; Alarm Package, FM0732; and Sump/Sewage Basins, FM0487.
137 Series - 47 lbs. 139 Series - 51 lbs.
Single Seal
Control Selection Listings
Model Volts-Ph Mode Amps Simplex Duplex CSA UL
M137/139 115 1 Auto 10.7 1 4 Y Y
N137/139 115 1 Non 10.7 2 or 3 2 or 4 Y Y
** BN137 115 1 Auto 10.7 ** 4 Y Y
D137/139 230 1 Auto 5.8 1 4 Y Y
E137/139 230 1 Non 5.8 2 or 3 4 Y Y
* H137/139 200-208 1 Auto 6.2 1 4 Y N
* I137/139 200-208 1 Non 6.2 3 4 Y N
* J137/139 200-208 3 Non 2.6 3 4 Y Y
* F137/139 230 3 Non 2.6 3 4 Y Y
* G137 460 3 Non 1.4 3 4 N N
* G139 460 3 Non 1.4 3 4 N N
RESERVE POWERED DESIGN
For unusual conditions a reserve safety factor is
engineered into the design of every Zoeller pump.
OPTIONAL PUMP STAND P/N 10-2421
Reduces potential clogging by debris.
Replaces rocks or bricks under the pump.
Made of durable, noncorrosive ABS.
Raises pump 2" off bottom of basin.
Provides the ability to raise intake by adding sections
of 1½" or 2" PVC piping.
Attaches securely to pump.
Accommodates sump, dewatering and efuent
applications.
NOTE: Make sure oat is free from obstruction.
"Easy assembly"
(pump & discharge pipe
not included.)
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
Your Peace of Mind is Our Top Priority
®
®
visit our web site:
www.zoeller.com
CAUTION
All installation of controls, protection devices and wiring
should be done by a qualied licensed electrician. All
electrical and safety codes should be followed including
the most recent National Electric Code (NEC) and the
Occupational Safety and Health Act (OSHA).