Spec Sheet
SELECTION GUIDE
1. Integral oat operated mechanical switch, no external control required.
2. For automatic use single piggyback variable level oat switch or double piggyback
variable level oat switch. Refer to FM0477.
3. See FM1228 for correct model of simplex control panel.
4. See FM0712 for correct model of duplex control panel or FM1663 for a residential
alternator system.
013225
5
10
15
20
25
0
2
4
6
LITERS
GALLONS
FLOW PER MINUTE
METERS
FEET
TOTAL DYNAMIC HEAD
0 100
20 40
200
60
300
80 100
400
120
500
140
PUMP PERFORMANCE CURVE
MODEL 266/267
MODEL
Meters Liters
266/267
5 4351.5 115
10 3223.0 85
15 1704.6 45
Shut-off Head: 20.5 ft.(6.2 m)
Feet Gal.
TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
SEWAGE AND DEWATERING
Model
MODEL COMPARISON CERTIFICATIONS
Seal Mode Volts Ph Amps HP Hz Lbs Kg Simplex Duplex cCSAus UL
M266/BN266 Single Auto 115 1 10.4 1/2 60 41.0 19 1 4 Y Y
N266 Single Non 115 1 10.4 1/2 60 41.0 19 2 or 3 2 or 4 Y Y
D266/BE266 Single Auto 230 1 5.5 1/2 60 41.0 19 1 --- Y Y
E266 Single Non 230 1 5.5 1/2 60 41.0 19 2 or 3 4 Y Y
H266 Single Auto 200-208 1 6.2 1/2 60 41.0 19 1 --- Y N
I266 Single Non 200-208 1 6.2 1/2 60 41.0 19 3 4 Y N
J266 Single Non 200-208 3 2.6 1/2 60 41.0 19 3 4 Y Y
F266 Single Non 230 3 2.6 1/2 60 40.0 18 3 4 Y Y
G266 Single Non 460 3 1.5 1/2 60 40.0 18 3 4 Y Y
M267/BN267 Single Auto 115 1 10.4 1/2 60 47.5 22 1 4 Y Y
N267 Single Non 115 1 10.4 1/2 60 47.5 22 2 or 3 4 Y Y
D267/BE267 Single Auto 230 1 5.5 1/2 60 47.5 22 1 --- Y Y
E267 Single Non 230 1 5.5 1/2 60 47.5 22 2 or 3 4 Y Y
H267 Single Auto 200-208 1 6.2 1/2 60 47.5 22 1 --- Y N
I267 Single Non 200-208 1 6.2 1/2 60 47.5 22 3 4 Y N
J267 Single Non 200-208 3 2.6 1/2 60 47.5 22 3 4 Y Y
F267 Single Non 230 3 2.6 1/2 60 47.5 22 3 4 Y Y
G267 Single Non 460 3 1.5 1/2 60 47.5 22 3 4 Y Y
© Copyright 2020 Zoeller
®
Co. All rights reserved.
502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | zoellerpumps.com
All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed
including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).
CAUTION
SPECIAL MODEL FEATURES
• Model 266 features a plastic base.
• Model 267 feature a cast iron base.
• Model 267 is available with a cast iron impeller, which is standard on all 3 Ph units.
• BN and BE models include a variable level pump switch.
• Additional cord lengths are available in 15' (5 m), 35' (11 m) and 50' (15 m).
• Minimum recommended basin size
(Small load applications)
Simplex - 18” x 30” (45.7 x 76.2 cm)
Duplex - 30” x 36” (76.2 x 91.4 cm)
• High water alarms available
Standard All Models:
266 - Weight 41 lbs. (18.6 kg)
267 - Weight 47.5 lbs. (21.5 kg)
Tank Diameter Volume Pumped
18” Simplex 8 Gal (30.2 L)
24” Simplex 15 Gal (56.8 L)
30” Duplex 22 Gal (83.3 L)
36” Duplex 33 Gal (124.9 L)
48” Duplex 60 Gal (227.1 L)
For “M” and “D” models, the approximate
volume pumped out per cycle are:
CAUTION
Maximum temperature of sewage or dewatering must be limited to 130°F (54°C).
For over 130°F (54°C), special quotation required.