Item Brochure

The ZOLL
®
SurePower
System
brings clinicians the confidence
that batteries will meet user
demands and removes the
uncertainty that drives costly
maintenance practices.
ADVANCING
RESUSCITATION.
TODAY.
®
SurePower Battery Pack
The SurePower Battery Pack has four times the energy density of traditional battery chemistries.
Its lithium-ion chemistry keeps pace with the growing demands of today’s defibrillators.
Longer life cycles and better capacity retention.
Eliminates guesswork by indicating runtime instead of non-specifi c capacity.
On-board memory stores both charging and use history.
SurePower Charger Station
The SurePower Charger Station is the cornerstone of this innovative maintenance system. With the
simple exchange of SurePower batteries in and out of the charger, calibration is automated and
history of use is recorded.
Icon-driven interface reports state of batteries.
Charges full range of ZOLL defi brillator batteries: SurePower, 4410, 4410 Smart, 4410
SmartReady, and XL batteries. Designed to accommodate future chemistry variants.
SurePower System Brings Value and Ef ciency to Battery Management
SurePower Battery Pack
Chemistry: Lithium-ion
Length: 16.5 cm (6.5 in.)
Width: 5.7 cm (2.25 in.)
Height: 4.4 cm (1.75 in.)
Weight: 0.77 kg (1.7 lbs)
Voltage: 10.8 Vdc
Capacity: 5.8 Amp Hours
User Interface: Display Button
LED Indicators: Runtime,
Calibration Required, Fault
Temperature:
Operation: 0° to 50°C (32° to 122°F)
Optimal Charging: 15° to 35°C (59° to 95°F)
Storage: -30° to 70°C (-22° to 158°F)
Charge Time: 4 Hours (for fully depleted
battery)
SurePower II Battery Pack
Chemistry: Lithium-ion
Length: 17.8 cm (7.0 in.)
Width: 9.3 cm (3.7 in.)
Height: 3.0 cm (1.2 in.)
Weight: 0.64 kg (1.4 lbs)
Voltage: 11.1 Vdc
Capacity: 6.6 Amp Hours
User Interface: Display Button
LED Indicators: Runtime,
Calibration Required, Fault
Temperature:
Operation: 0° to 50°C (32° to 122°F)
Optimal Charging: 15° to 35°C (59° to 95°F)
Storage: -30° to 70°C (-22° to 158°F)
Charge Time: 4 Hours (for fully depleted
battery)
SurePower Charger Station
Length: 40.6 cm (16 in.)
Width: 27.9 cm (11 in.)
Height: 15.5 cm (6 in.)
Weight: 6.8 kg (15 lbs) (without batteries)
Power Required: 90-265V AC (50-60 Hz)
Power Consumption: 200 Watts Maximum
Number of Battery Wells: 4
Temperature:
Operation: 0° to 50°C (32° to 122°F)
Optimal Battery Charging: 15° to 35°C
(59° to 95°F)
Storage: -40° to 70°C (-40° to 158°F)
Humidity: 5% to 95% Relative Humidity
User Interface: Test Button
Indicators: AC On, Battery Charging,
Battery Ready, Battery Testing, Fault
Compatible with: ZOLL Sealed Lead
Acid and Lithium-Ion Batteries, including
SurePower Battery, 4410 Battery,
4410 Smart Battery, 4410 SmartReady,
XL Battery.
Charging Protocols: AutoTest,
QuickCharge, FloatCharge, Manual Test
Communications: SMBUS, RS-232
Specifications
The SurePower Battery Pack
eliminates guesswork by
communicating in understandable
language: “Runtime”—30
minutes remaining, versus
“Capacity”—25% remaining.
©2015 ZOLL Medical Corporation. All rights reserved. SurePower and ZOLL are trademarks or
registered trademarks of ZOLL Medical Corporation in the United States and/or other countries.
All other trademarks are the property of their respective owners.
Printed in U.S.A. MCN HP 1308 0014
ZOLL Medical Corporation
Worldwide Headquarters
269 Mill Road
Chelmsford, MA 01824
978-421-9655
800-348-9011
For subsidiary addresses and fax numbers,
as well as other global locations, please
go to www.zoll.com/contacts.