Installation manual

26
[025] - [026] Group B Access Code Assignment
Refer to Addresses [009] - [010] for information on selecting Access Codes.
[027] - [032] For Future Use
[033] Group B Special Access Code Assignment
This address is used to assign the Auto-Arming, Quick-Arming, Keyswitch Arming and Central Station Arming
functions to Group B. Refer to Address [017] for programming instructions.
[034] - [040] For Future Use
[041] - [042] Group C Access Code Assignment
Refer to Addresses [009] - [010] for information on selecting Access Codes.
[043] - [048] For Future Use
[049] Group C Special Access Code Assignment
This address is used to assign the Auto-Arming, Quick-Arming, Keyswitch Arming and Central Station Arming
functions to Group C. Refer to Address [017] for programming instructions.
[050] - [056] For Future Use
[057] - [058] Group D Access Code Assignment
Refer to Addresses [009] - [010] for information on selecting Access Codes.
[059] - [064] For Future Use
[065] Group D Special Access Code Assignment
This address is used to assign the Auto-Arming, Quick-Arming, Keyswitch Arming and Central Station Arming
functions to Group D. Refer to Address [017] for programming instructions.
[066] - [079] For Future Use
[080] Bypass Inhibit
This feature prevents selected zones from being bypassed using the Mode 01 bypass command. When an Address
is entered, the 8 zone lights on the keypad will be used to indicate which zones are able to be bypassed:
When a zone light is OFF, that zone may be bypassed
When a zone light is ON, that zone may not be bypassed
For example, enter Address [080]. With the factory default program in place, zone lights 1 through 8 will be OFF,
indicating that zones 1 through 8 may be bypassed.
To select a zone, press the number key corresponding to the desired zone. For example, press 1 to select zone 1,
2 to select zone 2, and so on. When in other Addresses, refer to the Programming Worksheets to determine which
zone lights represent which zones.
Pressing a number key to select a zone will either turn the desired zone light ON or OFF:
If the zone light is ON, pressing the key will shut the light OFF
If the zone light is OFF, pressing the number key will turn the light ON
All zones programmed as Type 2 are automatically selected so that they cannot be bypassed.
[081] For Future Use
[082] - [083] Zone Transmission Delay Select
Zones may be programmed to delay transmission of alarms, allowing the user the opportunity to cancel alarms by
entering an Access Code. Zones that are to have a Transmission Delay are selected in Addresses [082] and [083]
by turning Zone Lights ON or OFF. If a Zone Light is ON, that zone will have the Transmission Delay programmed
in Mode 22 Address [027].
The user may use the [
][7] Cancel Alarm Command to cancel a delayed transmission.
Programming Mode 21