Do not attach paper clips, staples, or rubber bands to disks.
Do not try to open the sliding shutter th
at covers the disks (Figure 10 on
page 24).
Never touch the exposed disk area benea
th the sliding shutter.
CAUTION: Keep disks away from magnets and magnetized objects, includin g
telephones, power-supply adapters
,andmonitors.
Operation and Sto rage
The PRM and ZWT requi re special handling. The hard-disk drive and the
oppy-disk drive of the PRM must be protected from abusive han dli ng. To
protect the PRM and ZWT f rom damage, r
efer to the following information:
Do n ot turn off the PRM while the drive is accessing data.
Do not subject the PRM and ZWT to abusive shocks or vibrations.
When transporting the PRM and ZWT fr
om an outside environment to an
inside environment, allow the PRM to acclimate t o ambi ent temperature
before use.
Do not pla c e heavy objects on the PRM surface when cl osed or when
in operation.
Do not place a magnet on the PRM or ZWT.
Do not pour or splash liquid into o
r onto the PRM or ZWT.
Do not strike, scratch, nick, or otherwise abuse the touchscreen surface.
Do not disassemble the PRM or ZWT.
Remove any di sks from the drive pri
or to transporting the PRM.
Turn off the PRM, close all covers and doors, and put down the antenna
prior to transporting the PRM.
Unplug all external cables and cords prior to transporting the PRM.
Carefully se cure the stylus in its hold ing tray before closing the PRM’s
cover.
Operate t he PRM, ZWT and accessories within the following conditions:
Temperature range of 10°C to 35°
C (50°F to 95°F)
Humidity between 25% and 90%
Transport and store the PRM and ZWT within the following conditions:
Temperatures between -40°C and 7
0°C (-4 0°F and 158°F)
Humidity of 25% to 95%
Pressure of 50 kPa to 106 kPa (7.252 psi to 15.374 psi)
If the PRM has been stored in cold c
onditions (less than 10°C [50°F]) or warm
conditions (more than 35°C [95°F]), turn it on and let the fan run for at least
one h our befo re use. The PRM and ZWT are capable of continuous op eration
and will not shut off automatica
lly if they are unused f or an extended period
of time or if the PRM runs out of paper. Kee p the air intake and outlet free
from obstruction.