Specifications

Safety Check
Open the cabinet access door panel and check all pump unions to make sure they are hand tight. Loosening can occur during shipping
and handling. Check Shut-Off Valves and insure both are open fully, otherwise your pumps will not function (Page 6 Fig 3).
Turn on Power
Turn on power to spa at the circuit breaker box. The heater and pump 1 (low speed) will automatically activate.
Initiating Water Circulation
Depress JETS 1 topside pad on the control panel once to activate pump #1 in high speed and initiate maximum water flow to certain
jets.
Depress Aux and Blower Pads on the control panel to activate pumps 2 and blower.
Add Start-Up Chemicals
Add the spa water chemicals as recommended by your Hydrospa Spa dealer. Refer to (Page 7) for general guidance.
Place Cover On Spa
Keep the insulating cover in place anytime the spa is not in use it will reduce the time required for heating, thereby minimizing
operating cost. The time required for initial heat-up will vary depending on the starting water temperature and the capacity of your
spa. Smaller spas heat at a rate of approximately 8 to 10 degrees per hour; larger spas heat at about 4 to 6 degrees per hour. Lock
cover with safety locks when not in use.
WARNING: RISK OF INJURY. Always check water temperature carefully before entering spa.
Control Panel
Hydrospas Spas are equipped with a main control panel, located on the side of the spa as show above Figure 6.
The main control panel controls all of the spa functions, and uses indicator lights and an integrated LCD display to aid in determining
the status of the spa
Default System Operations: When power is applied, or there is a temporary lost of power, the system will initiate its default
programming. The filter cycle will begin 24-hous after the system has been powered up. The filtration cycle will be active for 1-hour
and will repeat every 12-hours The temperature will be maintained at 95 degrees F (35 degrees C).
Pump 1 Jets 1: Press this key once to turn Pump 1 on. A second press will turn it off. For dual speed pump operation; Press
this key once to turn Pump 1 onto Low speed, press this key a second time to turn Pump 1 onto High speed, a third press will turn the
pump off. A built-in timer will shut the pump off afer 20 minutes of operation unless done so manually. The Pump 1 Icon will appear
on the LCD while the pump is running in High speed and flash while it is in Low speed. If the filter icon appears, a filtration cycle
has begun and you will not be able to turn the pump off.
Pump 2 Jets 2: (If equipped) Press this key once to turn Pump 2 on. A second press will turn it off. A built-in timer will shut
the pump off after 20 minutes of operation unless done so manually. The Pump 2 Icon will appear while the pump is running in High
speed.
START-UP INSTRUCTIONS
Control Panel Display
Main Control Panel (CS6230-EX)
9
Figure 6
Jets 1
Aux
Light
Up
Down
TM
Engineered With Visual Illumination
Visual Diagnostic System
Blower