Specifications
Jets 1
Aux
Light
Up
Down
TM
Engineered With Visual Illumination
Visual Diagnostic System
Blower
Light Key: Press this key to turn the light on. A Second press will turn the Light off. The light will automatically shut off
after 2 hours. The Light Icon will appear while the light is on.
Temperature Set Keys: Press the Up Arrow key to increase the desired temperature. Press the Down Arrow key to
decrease the temperature. The temperature can be adjusted in 1 degree F increments from 59 degree F to 104 degree F (5 degree C to
40 degree C). The new setting will remain on the display for 5 seconds as a confirmation. During this time the Set Point icon will be
appear to let you know this is the desired and not the actual temperature. After 5 seconds the display will return to the current
temperature reading. When the temperature drops to 1 degree F below the set temperature, the heater will be turned on until the
temperature is 1 degree F above the set temperature. The heater icon will appear while the heater is on and flash when there is a call
for heat and the heater has not yet been activated.
START-UP INSTRUCTIONS
PROGRAMMING FILTRATION
The filter cycle occurs twice a day (every 12 hours) and the duration is user programmable. Press and hold the Light Key for
approximately 5 seconds to display the current duration. Use the Temperature Set Keys to either increase or decrease the duration.
The duration can be set from “0” (no filtration) to “12” (24 hours a day). Press the Light Key to save the new setting and to start the
filtration cycle. The Filter Indicator will illuminate on the display under the filter icon during an active cycle.
To prevent overheating of the spa water, the filtration cycle will be suspended any time the temperature reaches 2 degrees F (1 degree
C) above the set temperature. If the spa water cools to 1 degree F above the set temperature while the filtration cycle is still active
(filter indicator flashing) the filtration cycle will reactivate. The filtration cycle will be suspended if the user enters the spa and
activates a pump or blower manually. This is to prevent unnecessary operation of the ozonator. The cycle will be suspended for 40
minutes beyond the last manual activation of any accessory. The filter indicator will flash on the display while the filter cycle is
suspended.
ADDITIONAL FEATURES
Smart Winter Mode: If the system detects ambient conditions below a present a present factory setting, the system will automatically
activate the Smart Winter Mode for a period of 24 hours. In this mode, if a pump has not been powered in the last 2 hours, the system
will turn it on for one minute to prevent freezing. The filter Mode light indicator will flash while the pump is running in this mode.
Note: If you notice the pump coming on every 2 hours. This is the most likely cause. This will continue for a 24-hour period. This is
normal and is the systems protection against freezing.
Over Temperature Protection: If the water temperature exceeds 112 degrees F (44 degree C) at the Temperature sensor 3 flashing dots
will appear below the temperature display and the heater as well as all other outputs will shut off. After the water has cooled down
power to the spa must be cycled on then off to reset the system. If the spa water temperature does not seem to be elevated, the error
indication may have been caused by power water flow or electrical line interference (thunder storms, voltage surges, etc.). Simply
reset and monitor the system.
ERROR IDENTIFICATION
Three Flashing Dots with Pump Off
Pressure or Flow Switch Activated: If 3 flashing dots appear below the temperature display while there is
no pump operating, turn the pump on. If the 3 flashing dots went away this indicates that the pressure or
flow switch was activated although there was no water flow. (Contact your spa dealer or manufacturer).
Three Flashing Dots with Pump On
Pressure or Flow Switch Not Activated: If 3 flashing dots appear below the temperature display while the
pump(s) is operating, turn the pump(s) off. If the 3 flashing dots went away this indicates that the pressure
or flow switch was not activated although there was water flow. Note: A dirty filter limiting the water
flow will also cause this error message to appear. (Contact your spa dealer or manufacturer).
10
Jets 1
Aux
Light
Up
Down
TM
Engineered With Visual Illumination
Visual Diagnostic System
Blower
104104
104104
Blower Key. (If equipped) Press this key to turn blower on. A Second press will turn blower off. Blower will run for 20
minutes once you press the blower key unless you turn it off by pressing the blower key a second time. Blower can be used to cool