Specifications

13
FILTRATION
PROGRAMMING FILTRATION
Programming Filter Cycles: You may choose to filter the spa 1, 2 or 3 times per day as
required to keep the water clean and sanitary. Press and hold the pump key. The current
setting will be displayed. Press and hold the Temperature Set Key to increase or decrease
the frequency of the filtration cycles per day. The filter cycle is now set. The cycles will
repeat every 8, 12 or 24 hours within a 24-hour period starting from the time
programmed. It is recommended to schedule the filtration cycles so they do not interfere
with sleeping hours.
Programming Filter Cycle Duration: You may choose to filter your spa 60, 120, 180 or
480 minutes per cycle as required to keep the water clean and sanitary. Press both the
Light and arrow up key. The current duration of the filter cycle will be displayed. Press
and hold the Temperature Set key to increase or decrease the cycle. The duration is now
set. To start a filter cycle immediately, press and hold the Light key.
Note: If a Key is not pressed with 5 seconds during programming, the system will revert
back to the monitoring mode. If the Pump and/or light were turned on during the
programming process, turn them off. The system will revert back to display the water
temperature within 5 seconds.
Power Loss: Any interruption of power will cause the unit to reset and revert to the
default programming of 95
o
F set point temperature and 2, 1-hour filtration cycles.
ADDITIONAL FEATURES
Smart Winter Mode: If the system detects ambient conditions below a present factory
setting, the system will automatically activate the Smart Winter Mode for a period of 24
hours. In this mode, if a pump has not been powered in the last 2 hours, the system will
turn it on for a minute to prevent freezing. The filter Mode light indicator will flash
while the pump is running in this mode. Note: If you notice the pump coming on every 2
hours. This is the most likely cause. This will continue for a 24-hour period. This is
normal and is the systems protection against freezing.
Over Temperature Protection: If the water temperature exceeds 112
o
F at the
Temperature sensor 3 flashing dots will appear below the temperature display and the
heater as well as all other outputs will shut off. After the water has cooled down power
to the spa must be cycled on then off to reset the system. If the spa water temperature
does not seem to elevated, the error indication may have been caused by poor water flow
or electrical line interference (thunder storms, voltage surges, etc.). Simply reset and
monitor the system.
Power-Up Detection: Upon first powering the system or if a power outage occurs, the
display will flash until a key is pressed. This feature also lets the user know there has