Specifications
High Heat
Temperature Sensor Not in Dry-Well - Place sensor in dry-well.
Temperature Set Too High - Adjust Set Point.
High Ambient Temperature - Remove spa cover.
RCD Trips Occasionally
Lightning or Electrical Storm, Power Surge, Extremely Humid Conditions, or Radio Frequency Interference - Reset GFCI.
NOTE: GFCI must be properly grounded and bonded.
RCD Trips Immediately
Defective Component - Contact a qualified service technician or manufacturer for assistance.
No Light Operation
Light Bulb Defective - Replace bulb or contact your local dealer or manufacturer.
Reflector has Fallen Off - Replace deflector or contact your local dealer or manufacturer.
Light Not Plugged-In - Plug in the Light.
TROUBLESHOOTING
15
Nothing Operates
Main Breaker is Off - Set to On.
Sub-Panel Breaker Off - Set to On.
Equipment RCD Off - Set to On.
Power switch in Off position - Set to On
Power cord not plugged in - Plug in power cord.
Over or High Temperature Protection On - Refer to Error Identification (High Temperature)
No, Low Or Surging Water Flow
Air Lock in Plumbing System - “Bleed” the system.
Restricted Flow - Insure that the water shut-off valves are open and that suction fittings are not blocked by debris.
Dirty Filter - Clean or replace filter.
Low Water Level - Increase water level to recommended level.
No Low Speed Pump Operation.
Low Level Programming Incorrect - Contact your local dealer or manufacturer.
Over or High Temperature Protection On - Press button to reset.
Pump Not Plugged-In - Plug in the Pump.
No Jets Or Blower Operation
Blower or Pump Not Plugged-In - Plug in the Blower or Pump.
Over or High Temperature Protection On - Press button to reset.
No Therapy Jet Operation
Water Shut-Off Valves are Closed - Open Shut-Off valves.
Dirty Filter - Clean or replace filter
Jets Not Properly Adjusted - Adjust Jets properly.
Thermal Overload Tripping - Check for restricted flow of water.
Over or High Temperature Protection On - Press button to reset.
Water Leaks
Spa Overfilled - Adjust water level.
Too Many People in the Spa - Adjust water level.
Drain-Valve Left Open - Close drain valve.
Couplings or Unions Loose - Tighten or contact your local dealer, or manufacturer.
Plumbing / Connections Leaking - Contact your local dealer, or manufacturer.
Water in Air Blower Plumbing - Contact your local dealer, or manufacturer.
No Heat
Temperature Not Set Correctly - Adjust Set Point.
Over or High Temperature Protection On - Press button to reset.
Current Limiting On - LC Systems will not heat if High Speed or Blower is on. Contact your local dealer, or manufacturer.
No Power - Reset breaker at service panel.
Low Water Flow - Clean or Replace filter.