User's Manual

ZXSDRBS8802C100UserGuide
6.2InstallationPreparation
Beforetheinstallation,checktheenvironmentandensurethatrelatedinstallationtools,
instruments,anddocumentationareavailable.
1.Tool,instrument,anddocumentation
Tool
Adjustablewrenches,inner-hexagonspanner,straightscrewdriver,cross
screwdriver,pliers(sharp-nosepliers,diagonalpliers,andvices),tapemeasure,
antistaticwriststrap,andelectricpercussiondrill
Instrument
Gradienter,goniometer,andmultimeter
Documenta-
tion
ZXSDRBS8802C100UserGuide
2.Environmentcheck
Environmentrequirement
Indoorinstallation
Workingtemperature:–20~+45
Relativehumidity:5%~95%
Powerrequirement
Localpowersupply:85VACto264VAC
FacilityrequirementVerticalwall,levelceiling,verticalpole
6.3ChassisInstallation
ZXSDRBS8802C100iscompactinstructureandoccupiessmallfootprint.Therefore,
itcanbeexiblyinstalledinvariousindoorplaces.Inactualapplication,themost
commonlyusedinstallationmodesarewall-mountedinstallation,poleinstallation,and
ceilinginstallation.
6.3.1Pole-MountingaZXSDRBS8802C100
Context
ThediameterofthepoleusedtoinstallaZXSDRBS8802C100mustrangefrom20mm
to110mm.
Prerequisites
TheoperatorisresponsibleforprovidingandinstallingpoleswhileZTEcorporation
suppliesrelevantcomponentsandpartsforpole-mountedinstallationonly.
6-6
SJ-20110329145303-001|2011–10–25(R1.1)ZTEProprietaryandCondential