Chapter4OperationandMaintenance
ToolFunction
WrenchInstallsoruninstallstheRFcable
WaterprooftapeProvideswaterproofprotectionfortheRFcableconnector
StickerMarkstheconnectionofthecabletobereplaced(afterthe
replacement,thecablemustbereconnectedtotheplacewhere
itwas)
Moisture-proofantistaticbag
andcarton
StoresthefaultyRFcable
Steps
1.PowerofftheZXSDRR8978.
2.RemovethewaterprooftapeoftheRFcable.
3.LoosentheconnectorsoftheRFcablesbyusingthewrench.
4.Putthefaultycableintothemoistureproofantistaticbag.Labelthecablemodel,sector
IDandfaultinformationonthebag.Putthefaultycableintothecartonandlabelthe
sameinformationastheantisaticbag.
5.ConnecttheproperRFcableinaccordancewiththepreviousconnection,seeFigure
4-3.
Figure4-3ConnectingtheRFcable
Caution!
Duringtheuninstallationprocess,takeofftheconnectorcarefully.Trynottodamage
theconnector.
6.WraptheRFcableconnectorswithwaterprooftape,seeFigure4-4.
4-9