Hardware Development Guide of Module Product
All Rights reserved, No Spreading abroad without Permission of ZTEWelink 31
错误!未找到
用源。
ZM8620_V2
and the extreme working temperature range. Under the normal working temperature range, the testing
result of RF complies with the requirements of 3GPP specifications, and its function is normal. Under
the extreme temperature range, the RF index basically complies with the 3GPP specifications, and the
quality of data communication is affected to a certain extent, but its normal function is not affected.
ZM8620_V2 has passed the EMC test. Table 6–2 is the requirement for the testing environment, and
Table 6–3 lists out the instruments and devices that might be used during the test.
Table 6–2 Testing Environment
Working Condition
Min
Temperature
Max
Temperature
Remark
Normal working
condition
-10°C
60°C
All the indexes are
good.
Extreme working
condition
-20°C
70°C
Some indexes
become poorer.
Storage
-40°C
85°C
Storage environment
of ZM8620_V2
Table 6–3 Testing Instrument & Device
Testing Item
Instrument & Device
RF test
Comprehensive testing
device
RF cable
Tower antenna
Microwave darkroom
High/Low-temperature
running & storage test
High/Low-temperature
experimental box
Temperature shock test
Temperature shock
experimental box
Vibration test
Vibration console
6.3 Reliability Testing Environment
The reliability test includes the vibration test, high/low-temperature running, high/low-temperature
storage and temperature shock experiment test. Refer to Table 6-4 for the specific parameters.
Table 6–4 Reliability Feature