User Guide

Installation Maintenance Instructions
Model BVECXL LEAD-FREE*
Full Port Brass Ball Valve with
Thermal Expansion Control
(3/4" & 1")
Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects
or other reproductive harm.
WARRANTY: ZURN WILKINS Valves are guaranteed against defects of material or workmanship when used for the services recommended. If
in any recommended service, a defect develops due to material or workmanship, and the device is returned, freight prepaid, to ZURN WILKINS
within 12 months from date of purchase, it will be repaired or replaced free of charge. ZURN WILKINS’ liability shall be limited to our agreement
to repair or replace the valve only.
ISBVECXL (REV. 8/13)
ZURN WILKINS
1747 Commerce Way, Paso Robles, CA 93446 Phone:855-663-9876 Fax:805-238-5766
MAINTENANCE
The thermal expansion relief valve is designed to relieve
pressure periodically as the water heats. An average 40
gallon water heater will discharge approximately 1/3 of a
gallon during a reheat cycle. If the relief valve should fail
and discharge continuously, discard and replace with a new
control valve.
TYPICAL INSTALLATION
INSTALLATION INSTRUCTIONS
1.Beforeinstallationofvalve,ushlinethoroughlytore-
move all foreign matter from the line.
2. The ZURN WILKINS' Model BVECXL should be installed
on the cold water inlet of the water heater. Install so
that the thermal relief valve is on the downstream side
of the ball valve shut off.
3. CAUTION:TOAVOIDWATERDAMAGEDUETORE-
LIEF VALVE OPERATION, A DISCHARGE LINE
MUST BE CONNECTED TO THE RELIEF VALVE
OUTLET AND DIRECTED TO A SAFE DISPOSAL.
4. THE DISCHARGE LINE SHALL BE VERTICAL OR
DOWNWARD SLOPING AND TERMINATE AT LEAST
3 INCHES ABOVE THE DRAIN.
5. THREADS ARE PROHIBITED AT THE DISCHARGE
END OF THE RELIEF LINE.
6.Thedrainagelineofthereliefvalvemustbepipedin-
dependently of the water heater relief valve drain.
7.Thedischargelineshallbesecuredtopreventmove-
ment of the line during discharge.
C
B
A
D
400WOG
COLD WATER
HOT WATER
WATER HEATER
SAFE DRAIN
MODEL BVECXL
MODEL TP1100A
SAFE DRAIN
DIRECTION OF FLOW
MODEL
SIZE
CONNECTION
DIMENSIONS (approximate)
WEIGHT
A B C
D
in. mm in. mm in. mm in. mm lbs. kg
34-BVECXLC 3/4 20 SWEAT 3 15/16 100 1 15/16 49 2 13/16 71 1/8" FNPT 1 3/8 0.6
34-BVECXL 3/4 20 FNPT 2 3/4 70 1 5/8 41 2 13/16 71 1/8" FNPT 1 0.5
1-BVECXL
1 25 FNPT 3 1/4 83 1 15/16 49 2 15/16 75 1/8" FNPT 1 1/2 0.7
*This product contains a weighted average lead content less than 0.25% for wetted surfaces.
®
®
www.zurn.com