Submittal Sheet
Page 1 of 1
Zurn Industries, LLC | Wilkins
1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766
In Canada | Zurn Industries Limited
3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292
www.zurn.com
Rev. G
Date: 8/18
Document No. TMV-ZW1017XL
Product No. Mode ZW1017XL
Model ZW1017XL
Aqua-Gard
®
Tempering Mixing Valve
Application
Ideal for use where Lead-Free* valves are required. The Zurn
Wilkins Model ZW1017XL Aqua-Gard
®
Tempering Mixing
Valve, when installed at the hot water source, is designed to
mix hot and cold water in order to reduce the temperature
of the hot water in the distribution system to 122˚F(50˚C) or
less. The ZW1017XL's superior accuracy ensures safe water
temperature from minimum to maximum flow rate. Further,
multiple end configurations make this valve suitable for all
residential and most light commercial installations.
WARNING: This device should never be installed at the
point of use where the end user could change its setting.
Point of use device must be of the ASSE 1070 variety. It
is recommended that the ZW1017XL be installed with a
shut-off valve and thermometer in the tempered water line to
provide accurate and safe water mixing temperatures, to be
used in conjunction with ASSE 1070 device.
Standards Compliance
• ASSE® Listed 1017
• IAPMO® Listed
• CSA® Certified
• Meets the requirements of NSF/ANSI 61-9*
*(0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)
Materials
Body Low Lead Cast Bronze, ASTM B 584
Internal brass Low Lead Brass, ASTM B 927,
UNS C27450
Piston Polysufone
Guide Tube & Checks Noryl GFN2
Spring & Screen 300 Series Stainless Steel
Seals Nitrile Elastomer
Dimensions & Weights (do not include pkg.)
Features
Sizes: 3/8", 1/2", 3/4", 1"
Outlet Temp. Range 95-131°F(35-55°C)
Temperature Hot Supply 120-195°F max.
(49-90.5°C)
Temperature Cold Supply 40-75°F(4.4-23.8°C)
Set Temperature Accuracy +/- 4°F(2°C)
Max. Working Pressure (inlet) 145 psi
Max. Pressure Differential is 15 psi between Hot & Cold inlets
Flow rate @ 45 psi pressure loss 18 gpm
Min. Flow Rate 0.5 gpm
CPVC tailpiece - Maximum Hot water Temperature of
180°F @ 100 psi.
- Cold water rated temperature of
73.4°F @ 400 psi.
Options
PF - with Z-Bite™ push fit tailpiece connections
(1/2" - 1" only)
PR - with Z-Press™ press fit tailpiece connections
(3/4" - 1" only)
MODEL INLET & OUTLET
DIMENSIONS (approximate)
WEIGHT
A B C
in. mm in. mm in. mm lbs. kg
38-ZW1017XLCOMP 3/8" Compression 5 11/16 145 3 5/8 92 5 13/16 148 2 1
12-ZW1017XL 1/2" FNPT
5 7/16 138 3 3/8 86 5 1/4 133 2 1
12-ZW1017XLC 1/2" CU Sweat
12-ZW1017XLCPVC 1/2" CPVC 5 7/8 149 3 13/16 97 6 3/16 157 2 1
12-ZW1017XLPEX 1/2" Barb 5 9/16 141 3 1/2 89 5 9/16 141 2 1
12-ZW1017XLPEXF1960 1/2" Barb 5 3/8 137 3 5/16 85 5 1/4 133 2 1
34-ZW1017XL 3/4" FNPT
5 1/2 140 3 1/2 89 5 7/16 138 2 1
34-ZW1017XLC 3/4" CU Sweat
34-ZW1017XLCPVC 3/4" CPVC 5 7/16 138 3 3/8 86 5 5/16 135 2 1
34-ZW1017XLPEX 3/4" Barb 5 9/16 141 3 1/2 89 5 9/16 141 2 1
34-ZW1017XLPEXF1960 3/4" Barb 5 3/4 146 3 11/16 94 5 11/16 151 2 1
34-ZW1017XLM 3/4" MNPT 6 1/4 159 4 1/4 108 7 178 2 1
1-ZW1017XLC 1" CU Sweat 5 1/2 140 3 7/16 87 5 3/16 132 2 1
C
C
MIX
B
H
A
XL
FLOW RATES (GPM)
PRESSURE LOSS (PSIG)
0
20
40
60
0 51015
20
138
276
414
0.3 0.63 0.95
1.3
PRESSURE LOSS (kPa)
FLOW RATES (l/s)
MODEL ZW1017XL (STANDARD & METRIC)
NSF/ANSI 61-9
COLD WATER
DIRECTION OF FLOW
HOT WATER
WATER HEATER
SAFE DRAIN
TO HOT
APPLIANCES
MODEL TP1100A
T & P RELIEF VALVE
MODEL ZW1017XL
AQUA-GARD
TEMPERING
MIXING VALVE
TEMPERED WATER
®
Flow Characteristic
Domestic Water Heater
Application