Submittal Sheet

*REGULARLY FURNISHED UNLESS OTHERWISE SPECIFIED
Dimensional Data (inches and [mm]) are Subject to Manufacturing Tolerances and Change Without Notice
ZURN INDUSTRIES, LLC
SPECIFICATION DRAINAGE OPERATION
1801 Pittsburgh Ave.
Erie, PA 16514
Phone: 814/455-0921
Fax: 814/454-7929
World Wide Web: www.zurn.com
In Canada: ZURN INDUSTRIES LIMITED
3544 Nashua Drive
Mississauga, Ontario L4V1L2
Phone: 905/405-8272 Fax: 905/405-1292
®
SPECIFICATION SHEET
TAG _______
SUFFIXES
____ -AC Angular Underdeck Clamp
____ -AR Acid Resistant Epoxy Coated
____ -AW 3/4 [19] to 4 [102] Adj. Water Level Regulator
(Specify Height) (ZC Only)
____ -BS Bronze Mesh Screen Over Dome
____ -C Underdeck Clamp
____ -DE Deck Extension
____ -DP Top-Set
®
Deck Plate (Replaces both the -C and -R)
____ -DR Top-Set
®
Drain Riser
____ -DX Dex-o-tex Flange
____ -E Static Extension 1 [25] thru 4 [102] (Specify Ht.)
____ -EA Adjustable Extension Assembly
2 1/8 [54] thru 3 1/2 [89]
____ -EB Top-Set
®
Adjustable Extension Assembly
____ -FG Flush Grate (Replaces Dome Strainer)
____ -G Galvanized Cast Iron
____ -GD Galvanized Cast Iron Dome (ZC Only)
____ -HD 6 3/4 [171] High Aluminum Dome Strainer
(148 Sq. In. [955 cm
2
] Open Area) (ZA Only)
DWG. NO. 59285
REV. M
PRODUCT NO. Z100
DATE: 2/28/08 C.N. NO. 98161
Z100
15 [381] DIAMETER MAIN ROOF DRAIN
LOW SILHOUETTE DOME
PREFIXES
_____Z D.C.C.I. Body with Poly-Dome*
_____ZA D.C.C.I. Body with Aluminum Dome
_____ ZC D.C.C.I. Body with Cast Iron Dome
_____ZRB D.C.C.I. Body with Plain Bronze Dome
ENGINEERING SPECIFICATION: ZURN Z100
15 [381] Diameter roof drain. Dura-Coated cast iron body with
combination membrane flashing clamp/gravel guard and low
silhouette Poly-Dome.
OPTIONS
(Check/specify appropriate options)
PIPE SIZE (Specify size/type) OUTLET E BODY HT. DIM.
2 thru 6,8 [51 thru 152,203] _____ IC Inside Caulk 5 1/4 [133]
2 thru 6,8 [51 thru 152,203] _____ IP Threaded 3 3/4 [95]
2 thru 6,8 [51 thru 152,203] _____ NH No-Hub 5 1/4 [133]
2,3,4 [51,76,102] _____ NL Neo-Loc 4 9/16 [116]
6 [152] _____ NL Neo-Loc 5 7/16 [112]
____ -R Roof Sump Receiver
____ -SC Secondary Clamp Collar
____ -SS Stainless Steel Mesh Screen Over Dome
____ -ST Dome with Solid Top (ZA, ZC & ZRB Only)
____ -TC Neo-Loc Test Cap Gasket
(2 - 4 [51 - 102] NL Bottom Outlet Only)
____ -VP Vandal-Proof Secured Top
____ -W2 2 [51] Internal Water Dam
____ -W3 3 [76] Internal Water Dam
____ -W4 4 [102] Internal Water Dam
____ -84 Stainless Steel Perforated Gravel Guard
____ -85 Stainless Steel Perforated Extension
____ -89 2 [51] High External Water Dam
____ -90 90° Threaded Side Outlet Body
(2 thru 6 [51 or 152])
5,6 [127,152]
26 [12]
27 [12]
2,3,4 [51,76,102]
Approx.
Wt. Lbs.
[kg]
Dome Open Area
Sq. In. [cm
2
]
A
Pipe Size In.
103 [665]
8 [203]
28 [13]

Summary of content (1 pages)