Installation Sheet

AQUASPEC FAUCETS
MODEL - Z86500 SERIES
CENTERSET METERING
TECHNICAL INFORMATION
FLOW: 0.25 GPC MAXIMUM; PRESET AT FACTORY TO 10 TO 15 SECONDS @ 80 PSI ADJUSTABLE
MAXIMUM PRESSURE: 80 PSI
MAXIMUM TEMPERATURE: 140
O
F
F
®
INSTALLATION INSTRUCTIONS
1. THE WATER SUPPLY LINE MUST BE THOROUGHLY FLUSHED BEFORE FAUCET INSTALLATION.
2. REMOVE FAUCET BODY FROM CARTON AND PLACE FAUCET ON SINK.
3. ATTACH MOUNTING NUTS (#7A) ONTO SHANKS FROM UNDER SINK.
4. HAND TIGHTEN MOUNTING NUTS (#7A). DO NOT OVER TIGHTEN, YOU COULD DAMAGE THE FIXTURE.
5. ATTACH LAVATORY SUPPLY TO THE OUTLET OF THE SUPPLY STOP AND CONNECT TO FAUCET WITH RISER NUT
(#7B).
6. REMOVE MAINTENCE TAG FROM SPOUT END AND ATTACH TO SHANK OF FAUCET UNDER SINK FOR FUTURE
REFERENCE .
7. OPTIONAL - POP-UP (-P)/ GRID STRAINER (-G)/HANDICAP OFFSET GRID DRAIN (-GH):
INSTALL POP-UP OR GRID STRAINER IN SINK OUTLET AND PLUMB WASTE CONNECTION.
8. INSTALL SPRAY OUTLET (#6) INTO FAUCET AND HAND TIGHTEN.
9. TURN SUPPLY WATER ON AND OPERATE THE FAUCET WHILE CHECKING FOR LEAKS.
10. METERING CARTRIDGE IS FACTORY PRESET FOR A 10 TO 15 SECOND CYCLE AT 80 PSI, IF ADJUSTMENT IS
NECESSARY, SEE “ADJUSTING THE CYCLE TIME” SECTION (PAGE 2).
PAGE 1 OF 4
*
Form # CF102 Date: 11/21/09
C.N. No. 125541 Rev. P
IMPORTANTTHE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT
FOREIGN MATTER AND DEBRIS FROM CLOGGING AND/OR DAMAGING INTERNAL COMPONENTS
IMPORTANTTHE FAUCET HAS AN INTEGRAL SHANK FILTER ASSEMBLY INSTALLED IN THE BODY UNDER THE METERING
CARTRIDGE TO PREVENT FOREIGN MATTER AND DEBRIS FROM DAMAGING THE FAUCET. THE INTEGRAL FILTER MAY BE
REMOVED TO BE BACK-FLUSHED AND CLEANED IF INSUFFICIENT FLOW IS DETECTED. THE INTEGRAL SHANK FILTER
ASSEMBLY MUST BE RE-INSTALLED AFTER SERVICING TO ENSURE PROPER FUNCTIONING OF THE METERING CARTRIDGE.
- CAN USE QUARTER TURN CERAMIC DISK CARTRIDGE
ZURN INDUSTRIES, LLC
COMMERCIAL BRASS OPERATION
2640 SOUTH WORK STREET
FALCONER NY 14733
Phone: 1-800-997-3876
Fax: 1-919-775-3541
www.zurn.com
In Canada: ZURN INDUSTRIES LIMITED
3544 Nashua Drive
Mississauga, Ontario L4V1L2
Phone: 905/405-8272 Fax: 905/405-1292
*
*
FILTER REPLACEMENT
1) Remove handle and cartridge
2) Remove filter with
1
4
" Allen wrench
3) Replace or clean filter, re-install filter
4) Install cartridge and handle
(SEE OTHER SIDE FOR ADDITIONAL
INSTRUCTIONS)
INSTRUCTION GUIDELINES
1) Flush supply lines thoroughly before installing faucet.
2) Install 1.0 or 0.5 GPM spray outlet only, hand tighten.
3) See under handle for run time adjustment.
Need Help? 1-800-997-3876 or visit
www.zurn.com
(SEE OTHER SIDE FOR ADDITIONAL INSTRUCTIONS)
Part # CF1206
FILTER
(G67787)
SHANK
Remove this tag and place on supply line Remove this tag and place on supply line