Installation Guide

FV254 Rev. E 12/9/2014
Page 4
SPECIFICATION
Voltage:
Sensor Range:
Operating Water
Pressure:
Ambient
Temperature:
Operational Water
Temperature:
Aerator:
6 VDC
(4 “AA” Alkaline)
6” Approximate
20-80 psi
32ºF to 122ºF (0ºC to 50ºC)
35°F to 140°F (2°C to 60°C)
1.5 GPM Vandal-Resistant (Standard)
OPERATION
1.) Invisible light rays are continually emitted from the faucet
sensor.
2.) When the user’s hands come into range of the sensor’s
detection zone (factory set at approximately 6”), the beam
is reflected back to the sensor’s reciever and converted to a
low voltage electrical signal activating a solenoid valve.
3.) After the user removes their hands, the absense of
reflected light stops the low voltage electrical signal, closing
the valve. The circuit automatically resets for the next user.
4.) If an object is in view continuously for thirty seconds, the
faucet will automatically shut off. The faucet will remain off
until the object is removed. After the object is removed, the
faucet functions normally.
CARE AND CLEANING INSTRUCTIONS
DO NOT use abrasive or chemical cleaners to clean faucets as they will dull the luster and attack the chrome or special
decorative finishes. Use only mild soap and water, then wipe dry with a clean cloth or towel. While cleaning the bathroom tile
and floor, the faucet and electronics should be protected from splattering of water, cleaner, acids and cleaning fluids that can
damage the sensor faucet.
ZURN INDUSTRIES, LLC.
COMMERCIAL BRASS OPERATION
5900 ELWIN BUCHANAN DRIVE
SANFORD NC 27330
Phone: 1-800-997-3876
Fax: 919-775-3541
World Wide Web: www.zurn.com
In Canada: ZURN INDUSTRIES LIMITED
3544 Nashua Drive
Mississauga, Ontario L4V1L2
Phone: 905-405-8272 Fax: 905-405-1292
AquaSense
®
is a registered trademark of Zurn Industries, LLC.
Printed in the U.S.A.
TROUBLESHOOTING GUIDE
PROBLEM
FAUCET WILL NOT
FLOW WATER
POSSIBLE CAUSE
Water supply not turned on.
Batteries not connected.
Cable connection is not
fully engaged.
Low battery.
Solenoid valve inoperative.
Sensor/electronics are
inoperative.
Filter is plugged.
Solenoid valve is dirty.
FAUCET CONTINUES
TO RUN FOR MORE
THAN 30 SECONDS
OR DRIPS
TO DIAGNOSE
Check supply stops.
Check connections.
Check cable connection.
Flashing red light in sensor eye
indicates low battery.
Move hand in front of faucet to
see if solenoid valve is clicking.
Move hand in front of faucet
to see if solenoid valve is clicking.
See note in Step 4.
Shut off water supply. Remove
clean out cap.
Open the solenoid valve
and check for debris. Carefully
observe the way valve goes
together for reassembly.
REMEDY
Turn on water.
Reconnect batteries.
Remove battery, and disengage the cable
connection. Check cable connection for
broken pins and reconnect cable.Check
battery for voltage level and reinstall.
Remove batteries and replace with 4 new
alkaline batteries.
If clicking, open solenoid valve and clean it.
If not clicking, replace solenoid valve.
Remove the battery and short circuit the
battery terminals with allen wrench. This will
reset the electronics. Replace battery.
Clean the filter and reassemble.
Shut off water supply. Disassemble solenoid
and remove debris from diaphragm and/or
plunger tip. Reassemble solenoid.
®