Install Instructions
FV563 Rev. H 1/8/2018
Page 7
Adjustable modes and features selection:
To adjust features from default conguration, you must remove the
battery tray. Once battery tray is removed you will see the switches.
Purge Features:
The purge switches can be congured for 4 modes of operation: Disabled (standard conguration), 12 hour, 24 hours, or 48 hours.
Purge water ow duration is 2 minutes. Note: Purge activation occurs every switch selected time (0,12, 24, or 48 hours) after last
activation.
Flow Time:
There are 6 optional time congurations: 30 seconds (standard), 5s, 10s, 15s, 60s, & “Less Time-out”. The “Less Time-out” option
actually ceases water ow (turns off) after 20 minutes to limit chance of water damage in the event a sink drain becomes blocked .
Sensing Mode (DEFAULT):
During this mode the valve will shut off after hands are removed. If hands are not removed the time out delay will turn off the faucet
(ex: standard conguration is 30 seconds)) (See Sensing & Metering Mode ow chart above page)
Metering Mode:
When hands are detected by the sensor, water will run for ‘ X’ seconds (standard conguration is 30 seconds) before turning off. (See
Sensing & Metering Mode ow chart on following page)
Sensor Sensitivity: (Default setting: Low):
There are 4 sensitivity options, which can be selected to achieve the optimal detection performance related to the sink material,
shape, & nish. The faucet sensor sensitivity is congured during pack-out but the mode can be changed upon installation to
optimize the performance within the sink. Sensor sensitivity and sensor detection Modes A & B may be tried for various lighting
conditions, sink materials and shape.
Switch 7 controls the sensitivity
-On (default) is normal sensitivity for most sinks providing max range.
-Off set the sensor to a lower sensitivity level for sinks that cause false activation. The detection range maybe less for all hands.
Switch 8 controls sensor mode
-On (default) enables the mode that lters the effects of owing in the bottom of problematic sinks. Detection maybe less for some
hands.
-off disable the lter mode, so detection is expanded deeper into the sink for max detection range for all hands. Some sinks may
only be able to operate in this mode.
NOTE: After a conguration switch change has been made. Disconnect sensor cable from electronics box, wait 30 seconds, then
reconnect sensor cable and wait 30 additional seconds to allow the sensor to tune-in the sink characteristics. Calibration includes
characterizing the sink with water running into the bowl. This could be 5 to 60 seconds depending on conguration.
All switches shown in default mode.
Switch Posion: 1 2 3 4 5 6 7 8
Purge (Hours)
Disable:
12:
24:
48:
O
On
O
On
O
O
On
On
Time 30:
(Seconds) 5:
10:
15:
60:
Less Time-out
O
On
O
On
O
On
O
O
On
On
O
O
O
O
O
O
On
On
Mode Select
Sensing Mode:
Metering Mode:
O
On
Sensor Sensivity
Low: O
Normal: On
Mode A: O
Mode B: On
1 2 3 4 5 6 7 8
ON
OFF