1. Shut off the hot and cold water supplies. Remove the old faucet.
2. Place the plastic base plate on the sink deck above the holes.
In some installations, a sealant may be required to make a water tight seal
between the faucet base plate and the mounting surface. The installer should
verify the compatibility of the selected sealant with the mounting surface
manufacturer. Both plumber’s putty and silicone sealants are compatible with
Zurn faucets and xtures. Consult the mounting surface manufacture for their
recommendation of sealant.
3. Insert the mounting studs and stainless steel supply hoses through the holes in the sink
deck. Secure the faucet to the sink deck by threading on the faucet mounting nuts on to
the mounting studs.
Caution: Do not over tighten the faucet mounting nuts.
4. Connect the hot and cold water supplies. (While looking at the faucet viewed from the
front of the faucet) Connect the hot supply to the left faucet hose. Connect the cold water
supply to the right faucet hose. The faucet hose connections are 3/8" female compression
ttings.
5. Remove the faucet aerator and fully open the faucet water supply valves. Turn on the
Hot and Cold water supplies and ush supply lines of debris. Turn off the faucet valves
and check for leaks at all connections. Replace the aerator and hand tighten to prevent
leaks. For additional grip you can wrap the aerator with a rubber band.
6. Spray hose & handset Assembly (Model Z7872C-XL only) unit installation. Install the
plastic handset holder with shank into the mounting ange and hole in the sink. Attach
mounting nut to shank and tighten to secure to sink. Slide the tting end of the spray
hose through the handset holder and attach the tting onto the male threaded end of the
faucet housing. Tighten until snug. Slide the hose down through the handset holder until
the spray unit rests ush with the sink. Check for leaks. Tighten tting if necessary.
Helpful Hint: Before working on the faucet,
cover the drain with sheets of newspaper or
cardboard material. This will keep the small
parts from falling through the drain.
1. Turn off the water supplies.
2. Remove the color red/blue button.
Loosen the handle set screw.
3. Pull off the lever handle. Loosen
the chrome bonnet nut by turning
counterclockwise.
4. Unscrew the chrome escutcheon
nut. Unscrew and remove the brass
retaining nut counterclockwise.
5. Pull out the ceramic control cartridge.
If necessary use small pliers to
grab the valve stem. Do not use a
screw driver to pry up the ceramic
cartridge. Damage of the cartridge
can result if prying is performed.
6. Check the interior of the bore for
debris. At the bottom of the housing
bore area check the three holes for
debris. Clean if necessary. If the
parts look ne re-install the ceramic
cartridge assembly. Use a silicone
base lubricant on the o-ring of the
cartridge before re-installation.
If a new ceramic control cartridge is
required use: RK7872C-XL-CART
7. When installing the ceramic control
cartridge assembly, make sure
that the two smaller o-rings on the
bottom are properly installed within
the o-ring grooves of the cartridge.
Lightly install the cartridge into the
faucet housing so that the pins of
the cartridge line up with the small
dowel holes at the bottom of the
faucet housing. The alignment holes
will appear at the 5 and 7 o'clock
positions at the base of the faucet
housing. Push the control cartridge
all the way down until it is fully
seated into the alignment dowel
holes. Proper installation will allow
about 1/8" of threads showing above
the cartridge assembly.
8. Re-install the brass retaining nut
into the faucet housing by turning
the nut in a clockwise rotation.
9. Re-install the chrome escutcheon
nut until snug.
10. Turn on the water supply. Check
for leaks. Re-adjust the retaining
nut if necessary. Reinstall the lever
handle. Reinstall the color button.
Always use Zurn parts when performing
routine maintenance. The use of non-Zurn
parts will void your warranty. After any
maintenance is performed on the valve, ush
the system as noted in the Faucet Test and
Adjustment section of the instructions.
Installation Instructions Maintenance Instructions (ceramic control cartridge replacement)
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov