Installation Guide
MAINTENANCE
1. YOUR ZURN AQUASPEC BUBBLER HAS A HIGHLY POLISHED NICKEL CHROME PLATED FINISH. CLEAN WITH SOAP
AND WATER OR A MILD CLEANER WHICH IS SAFE FOR CHROME PLATING. DO NOT USE ACIDS OR TOILET BOWL
CLEANER AS THEY WILL DAMAGE THE FINISH.
2. POPPET ASSEMBLY (#3) REMOVAL AND REPLACEMENT
2.1. REMOVE COLORED INDEX BUTTON (#1C) FROM HANDLE (#1A)
2.2. LOOSEN SET SCREW (#1B) IN HANDLE WITH 3/32” ALLEN WRENCH
2.3. PULL UP ON HANDLE TO REMOVE FROM STEM (#2C) OF HANDLE NUT ASSEMBLY (#2)
2.4. REMOVE HANDLE NUT ASSEMBLY (#2) USING 1-1/8” HEX 6-POINT SOCKET
2.5. REMOVE POPPET ASSEMBLY (#3) BY LIFTING OUT OF BUBBLER BODY (#7). IT MAY BE NECESSARY TO OPEN
THE SUPPLY STOP SLIGHTLY TO ALLOW WATER PRESSURE TO PUSH THE METERING CARTRIDGE UPWARD.
2.6 INSPECT POPPET ASSEMBLY (#3) FOR WORN PARTS, DAMAGED PARTS AND ANY CONTAMINATION THAT MAY BE
PREVENTING THE POPPET ASSEMBLY FROM MOVING FREELY OR SEATING. OTHER THAN CLEANING ANY
TRAPPED DEBRIS, THERE ARE NO SERVICEABLE PARTS IN THE POPPET ASSEMBLY. CONTAMINATED OR
DAMAGED POPPET ASSEMBLIES SHOULD BE REPLACED.
2.7 REVERSE STEPS 1.1 THROUGH 1.5 FOR RE-ASSEMBLY. POPPET ASSEMBLY (#3) WILL SIT SLIGHTLY ABOVE
BODY (#7) PRIOR TO MOUNTING OF HANDLE NUT ASSEMBLY. TIGHTEN CAP (#2F) WITH 1-1/8” HEX 6-POINT
SOCKET UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE BUBBLER IS
RUNNING. HOLD DOWN HANDLE (#1) WHILE TIGHTENING SET SCREW (#1B) TO ENSURE PROPER SEATING
3. IT MAY BE NECESSARY TO REPLACE OR BACK FLUSH THE IN-LINE SHANK FILTER PERIODICALLY TO REMOVE
COLLECTED SEDIMENT AND DEBRIS. THE IN-LINE SHANK FILTER (#6) MAY BE REMOVED USING A 1/4” ALLEN
WRENCH.
1. ROTATE FLOW CONTROL (#8) WITH 5/32 ALLEN WRENCH UNTIL THE DESIRED FLOW IS ACHIEVED
ADJUSTING THE FLOW ON ZURN BUBBLER
PAGE 2 OF 3
REPLACEMENT PARTS
HANDLE NUT ASSEMBLY G60561
POPPET ASSEMBLY G62682
HANDLE ASSEMBLY G60522
FILTER ASSEMBLY G67787
Metering Faucet Trouble Shooting Guide
Problem Cause Solution
No water is coming out
bubbler & all supply
stops are on.
Shut off water. Remove filter assembly
(#6) from lavatory supply stop and rinse
debris from filter. Replace filter assembly
and turn on water to bubbler.
Clogged filter assembly.
Bubbler will not shut off.
Cartridge is damaged.
Replace metering
cartridge G62682
Form # CF1060 Date: 12/20/11
C.N. No. 128445 Rev. G