Use and Care Manual

FV237 Rev. F 6/25/2018
Page 5
WIRING DIAGRAM
TROUBLE SHOOTING GUIDE
Delay Flush = User must
leave the sensor range for
3 seconds before a ush is
generated.
24 Hour Flush = Unit will
automatically ush 24 hours
after the last use.
PROBLEM CAUSE SOLUTION
Yellow L.E.D. light ashes 3 times
when there are no
users.
Front of Object Lock Sensor is
covered or Object Lock Sensor is
set too far out, registering the
opposite wall or door as a user.
Remove item covering sensor or
adjust Object Lock Sensor activation
distance. (See Appendix B – Adjust-
ing the E-Z Flush.)
Yellow L.E.D. light ashes continu-
ously when Object
Lock Sensor is activated by a user.
E-Z Flush unit is in 10-minute
start-up mode (when rst activated),
or Sensor Range Reset
Button has been depressed.
Yellow L.E.D. light will ash only 3
times, acknowledging a user is in
view after the 10-minute start-up
mode.
Red L.E.D. light ashes. Batteries need replacing. Replace batteries.
Not enough water to xture or too
much water to xture.
Diaphragm damaged or valve
control stop improperly adjusted.
Replace diaphragm and/or adjust
valve control stop.
Valve will not operate. Object Lock Sensor range set too
close to E-Z Flush, batteries are
dead, or water supply is turned off.
Adjust Object Lock Sensor, replace
batteries, or turn water on. If the E-Z
Flush does not begin to function,
call Customer Service at 1-800-997-
3876.
Valve does not shut off. Dirt or debris preventing diaphragm
from functioning properly.
Remove dirt or debris, check by-
pass hole in diaphragm.
Valve does not ush even after Ob-
ject Lock Sensor has been adjusted.
Batteries are dead. Replace batteries. If the E-Z Flush
does not begin to function, call Cus-
tomer Service at 1-800-997-3876.