User Manual
Safety Precautions Cont.
The F8-200 is equipped with a temperature sensor and fan control. In
the unlikely event that the fan malfunctions or the xture operates at
too high a temperature, the xture will put itself into a safe mode and
limit the light output. At rst, the xture will drop its maximum power
to 80% of full output. The display will ash a warning for
“TEMPERATURE” to let the operator know it is running at reduced
power. If the temperature continues to be out of range, the unit will
continue to protect itself and operate at 50% of maximum output and
display a “TEMPERATURE” mode warning. All of these extreme use
case power reductions are rare. The light will return to normal
operation when cool and power cycled. The unit can and will operate
at 50% power without the assistance of a fan. In the unlikely event the
temperature reaches a critical state, the xture will turn itself off. “FAN
FAULT” will display in the unlikely event of a fan obstruction or failure.
Please refer any error codes to Zylight’s service department.
• To reduce the risk of electrical shock or re, do not submerge this xture in water.
• Do not spill large amounts of water or other liquids into or on to your xture.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Do not
attempt to remove or break off the ground prong from the electrical cord. This prong is
used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the lens under any conditions. There are no user serviceable parts inside.
• Never operate this xture if the Fresnel lens is removed.
• Never plug this unit into a dimmer pack.
• Always be sure to mount this xture in an area that will allow proper ventilation. Allow at
least 6" (15cm) between this device and a wall.
• Do not attempt to operate this xture if it becomes damaged.
• During long periods of non-use, disconnect the xture's main power.
• Always mount this xture in safe and stable matter. Always use a safety cable as part of
a secure installation. This includes securing the barn doors with a safety cable.
• Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to the point they exit from the xture.
• Cleaning: The xture should be cleaned only as recommended by the manufacturer. See
page 10 for cleaning details.
• Heat: The instrument should be situated away from heat sources such as radiators, heat
registers, stoves, or other appliance (including ampliers) that produce heat.
• The xture should be serviced by qualied service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the instrument.
C. The instrument has been submerged in water.
D. The standard AC power supply has been exposed to water, prolonged weather, or
dampness.
E. The instrument does not appear to operate normally or exhibits a marked change in
performance.