Swimming Pool User Manual

Model CS9B-THO and CS9BE-THO Shown
4 Models: CS9B-THO Temperature, Humidity, Occupancy
CS9B-THOC Temperature, Humidity, Occupancy, and CO2
CS9BE-THO Temperature, Humidity, Occupancy w/Ethernet Connection
CS9BE-THOC Temperature, Humidity, Occupancy, and CO2 w/Ethernet Connection
Features---All Models except as Noted:
All-in-One Multi-Function Controllers: THO models: Temperature, Humidity (dehumidification only), Occupancy
THOC models: Temperature, Humidity (dehumidification only), Occupancy and CO2 (On/Off control)
Adaptive Occupancy Scheduling:
1. Automatically learns the start of the 1
st
persistent occupancy for each day of the week using on-
board motion sensor to create a 7-day start of occupancy schedule
2. Continuously adapts the schedule with any changes to the usage pattern
3. Provides adaptive optimized space warm-up or cool-down with respect to the learned start of
occupancy for each day
User-friendly, high contrast, backlit LCD display with Continuous β€œOn” option
Simple 5-Button user interface for menu-driven configuration and operation
No need for connected PC or programming
All models are BACnet capable for MS/TP, EIA-485 using shielded twisted pair for networking
BACnet is an ANSI and ISO global standard open communications protocol developed by ASHRAE
The β€œE” Ethernet versions offer alternate method of networking using CAT 5 port on the sub-base
9-relay output for complete and reliable HVAC system control
F or C temperature option
Conventional modes: 1H/1C, 2H/2C, 1H/2C, 2H/1C, 2H/3C if configured for economizer
Heat Pump modes: 1-Stage (2H/1C), 2-Stage (3H/2C, 3H/3C if configured for economizer)
Wide Range Occupancy Sensor: senses up to 33 feet distance, 120-degree horizontal and 100-degree vertical
sensing from controller location. Remote occupancy sensor(s) can be added for extreme applications
Built-in alarms and trend logs
Configurable password protection with 3 levels of password-protected access
Programmable (7-day, 5+2, individual days, up to 12 holidays) or non-programmable
No batteries, retains date/time settings for 72-hours during power loss
All settings except time maintained permanently in non-volatile memory until changed by user
Auto or manual changeover option
Fan Operation: Auto/On/Programmed (Programmed is On during Occupied, Auto during Un-Occupied)