Network Device User's Guide Omni 56K Plus Series

Omni 56K Plus Series User’s Guide
Command Sets 4-13
Table 4-10 Class 2 Command Responses
RESPONSE VALUE FUNCTION AND DESCRIPTION
+FPOLL Remote polling indication.
+FPTS:n Receive page transfer status response; refer to +FPTS=n
command.
+FTSI:"string" Report remote ID response TSI.
+FVOICE Transition to Voice response.
Class 2 Flow Control
Flow control is necessary to match the DTE-DCE data rate to the line-signaling rate while transmitting
or receiving Group 3 (T.4) data. In Class 2 fax mode, both hardware (RTS/CTS) and software
(XON/XOFF) flow control are enabled.
4.2.3 Service Class 2.0 Commands
Table 4-11 Service Class 2.0 Commands
COMMAND DESCRIPTION VALUE
ATD Dial and originate a call
ATA Answer a call
+FDT Transmit phase C data command: releases
the DCE to proceed with the negotiation.
+FDR Receive phase C data command: initiates
document reception.
+FKS Terminate a Session, orderly fax abort.
+FIP Initialize Service Class 2.0 Parameters.
+FCLASS=n Service Class Identification and Control n=0,1,2.0,8;refer to the +FCLASS
Class 1 command
+FMI? Identify DCE Manufacturer ZyXEL
+FMM? Identify DCE Omni 56K Plus
+FMR? Identify DCE Revision Vx.x
Establish DCE Capabilities
Vertical Resolution vr=0:Normal;98 lpi
vr=1:Fine;196 lpi
+FCC=vr,br,wd,ln,df,ec,bf,st
Bit Rate br=0:2400 bps
br=1:4800 bps
br=2:7200 bps
br=3:9600 bps
br=4:12000 bps
br=5:14400 bps