User guide
Table Of Contents
- Part1
- Part2
- Part2
- Part3
- Part4
- Part5
- Dynamic Link Aggregation
- Link Aggregation ID
- RADIUS
- Configuring RADIUS Server Settings
- Configuring IEEE802.1x
- Supported MIBs
- SNMP Traps
- Configuring SNMP
- Setting Up Login Accounts
- Requirements for Using SSH
- HTTPS Example
- Internet Explorer Warning Messages
- Netscape Navigator Warning Messages
- Login Screen
- Strict Priority Queuing (SPQ)
- Weighted Round Robin Scheduling (WRR)
- DiffServ
- DSCP and Per-Hop Behavior
- DHCP “Relay Agent Information Option”
- DHCP Relay Agent Circuit ID Sub-option Format
- Part6
- Part7
- Switch Configuration File
- Access Priority
- The Console Port
- Telnet
- List of Available Commands
- Detailed Command Information
- Logging Out
- User Mode
- Enable Mode
- Configure Mode
- config-vlan Commands
- interface Commands
- show system-information
- show hardware-monitor
- show ip
- show logging
- show interface
- show mac address-table
- Backing up Configuration
- Restoring Configuration
- Using a Different Configuration File
- Resetting to the Factory Default
- no mirror-port
- no https timeout
- no trunk
- no port-access-authenticator
- no ssh
- interface
- bpdu-control
- broadcast-limit
- bandwidth-limit
- mirror
- gvrp
- ingress-check
- frame-type
- vlan-trunking
- spq
- wrr
- egress set
- qos priority
- name
- speed-duplex
- Static Entries (SVLAN Table)
- Dynamic Entries (DVLAN Table)
- GARP Status
- GARP Timer
- GVRP Timer
- Enable GVRP
- Disable GVRP
- Set Port VID
- Set Acceptable Frame Type
- Enable or Disable Port GVRP
- Modify Static VLAN
- Delete VLAN ID

Dimension GS-3012 Gigabit Ethernet Switch
Cluster Management 25-5
Figure 25-5 Configuring Cluster Management
The following table describes the labels in this screen.
Table 25-4 Configuring Cluster Management
LABEL DESCRIPTION
Clustering
Manager
Active Select Active to have this switch become the cluster manager switch. A cluster can only have one
manager. Other (directly connected) switches that are set to be cluster managers will not be visible
in the Clustering Candidates list. If a switch that was previously a cluster member is later set to
become a cluster manager, then its Status is displayed as Error in the Cluster Management
Status screen and a warning icon (
) appears in the member summary list below.
Name Type a name to identify the Clustering Manager. You may use up to 32 printable characters (no
spaces are allowed).
VID This is the Management VLAN ID and is only applicable if the switch is set to 802.1Q VLAN. All
switches must be in the same management VLAN group to belong to the same cluster. Switches
that are not in the same management VLAN group are not visible in the Clustering Candidates
list. This field is ignored if the Clustering Manager is using Port-based VLAN.
Apply Click Apply to save these changes to the switch.