User's Manual

Omni 56K Plus Series User’s Guide
Command Sets 4-15
Table 4-11 Service Class 2.0 Commands
COMMAND DESCRIPTION VALUE
nsr= 1:Non-standard frames are
reported.
+FIE=n Procedure Interrupt parameter n=0:Disable
n=1:Enable
+FPS=n Page Transfer Status n=1:Received page is good.
n=2:Page is bad; retrain is
requested.
n=3:Page is good; retrain is
requested.
n=4:Page is bad; procedure
interrupt is requested.
n=5:Page is good; procedure
interrupt is requested.
+FLO=n Flow Control Select n=0:No flow control
n=1:Sets XON/ XOFF software
flow control
n=2:Sets CTS/RTS hardware flow
control
+FPR=n Serial Port Rate Control n=0:Automatic DTE rate detection
by the DCE
n>0:Serial rate is fixed at the
value multiplied by 2400 bps.
+FBO=n Phase C Data Bit Order n=0:Selects direct bit order
n=1:Selects reversed bit order
+FEA=n Phase C Received EOL alignment n=0:EOL patterns are as received
+FCR=n Capability to Receive n=0:Not receive message data or
poll a remote device.
n=1: Receives message data or
poll a remote device.
+FCQ=<rq>,<tq> Copy Quality disable/enable rq= 0:Receive copy quality check
is disable.
rq=1:Receive copy quality check
is enable.
tq= 0:Transmit copy quality check
is disable.
tq=1:Transmit copy quality check
is enable.
+FRQ=pql,cbl Receive Quality Thresholds pgl= 0-64h:Specifies the
percentage of good lines
cbl= 0-ffh:Specifies the maximum
tolerable number of consecutive
bad lines.