Chapter 8 Basic Setting
GS1920 Series User’s Guide
75
Click the PoE Setup link in the Basic Setting > PoE Status screen. The following screen opens.
Figure 58 Basic Setting > PoE Setup
The following table describes the labels in this screen.
Table 18 Basic Setting > PoE Setup
LABEL DESCRIPTION
PoE Mode Select the power management mode you want the Switch to use.
• Classification - Select this if you want the Switch to reserve the Max Power (mW) to each PD
according to the priority level. If the total power supply runs out, PDs with lower priority do not
get power to function.
• Consumption - Select this if you want the Switch to manage the total power supply so that
each connected PD gets a resource. However, the power allocated by the Switch may be
less than the Max Power (mW) of the PD. PDs with higher priority also get more power than
those with lower priority levels.
Port This is the port index number.
* Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first to set
the common settings and then make adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you make them.
PD Select this to provide power to a PD connected to the port.
If left unchecked, the PD connected to the port cannot receive power from the Switch.
PD Priority When the total power requested by the PDs exceeds the total PoE power budget on the Switch,
you can set the PD priority to allow the Switch to provide power to ports with higher priority.
Select Critical to give the highest PD priority on the port.
Select High to set the Switch to assign the remaining power to the port after all critical priority
ports are served.
Select Low to set the Switch to assign the remaining power to the port after all critical and high
priority ports are served.