User manual

Chapter 43 Maintenance
GS2210 Series User’s Guide
358
Make sure you have downloaded (and unzipped) the correct model firmware and version to your
computer before uploading to the device.
Be sure to upload the correct model firmware as uploading the wrong
model firmware may damage your device.
Click Management > Maintenance > Firmware Upgrade to view the screen as shown next.
Figure 262 Management > Maintenance > Firmware Upgrade
Type the path and file name of the firmware file you wish to upload to the Switch in the File Path text box
or click Choose File to locate it. Firmware upgrades are only applied after a reboot. Click Upgrade to
load the new firmware.
After the firmware upgrade process is complete, see the System Info screen to verify your current
firmware version number.
Table 179 Management > Maintenance > Firmware Upgrade
LABEL DESCRIPTION
Name This is the name of the Switch that you’re configuring.
Version The Switch has two firmware sets, Firmware 1 and Firmware 2, residing in flash.
Running shows the version number (and model code) and MM/DD/YYYY creation date
of the firmware currently in use on the Switch (Firmware 1 or Firmware 2). The firmware
information is also displayed at System Information in Basic Settings.
Firmware 1 shows its version number (and model code) and MM/DD/YYYY creation
date.
Firmware 2 shows its version number (and model code) and MM/DD/YYYY creation
date.
Current Boot Image This displays which firmware is currently in use on the Switch (Firmware 1 or Firmware 2).
Config Boot Image Select which firmware (Firmware 1 or Firmware 2) should load, click Apply and reboot the
Switch to see changes, you will also see changes in the Current Boot Image field above as
well.