User manual

Chapter 44 Access Control
GS2210 Series User’s Guide
379
An OID (Object ID) that begins with “1.3.6.1.4.1.890.1.15” is defined in private MIBs. Otherwise, it is a
standard MIB OID.
Table 193 SNMP System Traps
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
coldstart coldStart 1.3.6.1.6.3.1.1.5.1 This trap is sent when the Switch is turned
on.
warmstart warmStart 1.3.6.1.6.3.1.1.5.2 This trap is sent when the Switch restarts.
fanspeed zyHwMonitorFanSpeedOutO
fRange
1.3.6.1.4.1.890.1.15.3.26.2.1 This trap is sent when the fan speed goes
above or below the normal operating
range.
zyHwMonitorFANSpeedOut
OfRangeRecovered
1.3.6.1.4.1.890.1.15.3.26.2.6 This trap is sent when the fan speed is
recovered from the out of range to normal
operating range.
temperature zyHwMonitorTemperatureOu
tOfRange
1.3.6.1.4.1.890.1.15.3.26.2.2 This trap is sent when the temperature goes
above or below the normal operating
range.
zyHwMonitorTemperatureOu
tOfRangeRecovered
1.3.6.1.4.1.890.1.15.3.26.2.7 This trap is sent when the temperature is
recovered from the out of range to normal
operating range.
voltage zyHwMonitorPowerSupplyVo
ltageOutOfRange
1.3.6.1.4.1.890.1.15.3.26.2.3 This trap is sent when the voltage goes
above or below the normal operating
range.
zyHwMonitorPowerSupplyVo
ltageOutOfRangeRecovere
d
1.3.6.1.4.1.890.1.15.3.26.2.8 This trap is sent when the power supply
voltage is recovered from the out of range
to normal operating range.
reset zySysMgmtUncontrolledSyste
mReset
1.3.6.1.4.1.890.1.15.3.49.2.1 This trap is sent when the Switch
automatically resets.
zySysMgmtControlledSystem
Reset
1.3.6.1.4.1.890.1.15.3.49.2.2 This trap is sent when the Switch resets by
an administrator through a management
interface.
zySysMgmtBootImageIncons
istence
1.3.6.1.4.1.890.1.15.3.49.2.3 This trap is sent when the index number of
image which is loaded when the Switch
starts up is different from what is specified
via the CLI.
RebootEvent 1.3.6.1.4.1.890.1.5.1.1.2 This trap is sent when the Switch reboots by
an administrator through a management
interface.
timesync zyDateTimeTrapTimeServerN
otReachable
1.3.6.1.4.1.890.1.15.3.82.3.1 This trap is sent when the Switch’s date and
time is not manually entered or the
specified time server is not reachable.
zyDateTimeTrapTimeServerN
otReachableRecovered
1.3.6.1.4.1.890.1.15.3.82.3.2 This trap is sent when the Switch’s real time
clock is up to date.
intrusionlock zyPortIntrusionLock 1.3.6.1.4.1.890.1.15.3.61.3.2 This trap is sent when intrusion lock occurs
on a port.
loopguard zyLoopGuardLoopDetect 1.3.6.1.4.1.890.1.15.3.45.2.1 This trap is sent when loopguard shuts down
a port.