3 Enable the MDU’s VDSL2 port (port 1 in this example) and check the status.
4 Configure VLAN flow settings for the VDSL port on the remote ONT the same as in step 9 on page
64 except it’s for ONT 102.
OLT2406# config
OLT2406(config)# remote ontvdsl ontvdsl-6-1-102-1-1
OLT2406(config-ontvdsl)# no inactive
OLT2406(config-ontvdsl)# exit
OLT2406(config)# exit
OLT2406# show remote ontvdsl line-template ontvdsl-6-1-102-1-1
------------------------------------------------------------------------------
ontvdsl-6-1-102-1-1: line template = DEFVAL
------------------------------------------------------------------------------
OLT2406(config)# remote uniport uniport-6-1-102-1-1
OLT2406(config-remote-uniport)# queue tc 1 priority 1 weight 0 usbwprofname voice dsbwprofname voice bwsharegroupid 1
OLT2406(config-remote-uniport)# vlan 10 network 10 ingprof voip aesencrypt disable active on
OLT2406(config-remote-uniport)# exit
OLT2406(config)# exit
OLT2406# show remote uniport uniport-6-1-102-1-1 queue
Uniport TrafficClass Priority Weight UsBwProfileName DsBwProfileName BwShareGroupId
-------------------------------------------------------------------------------------------------
uniport-6-1-101-1-1 1 2 0 voice voice 1
OLT2406# show remote uniport uniport-6-1-102-1-1 vlan 10
|AID | UNI-VID Status NNI-VID Tag PBit_Prof DSCP_to_PBIT Ing_Prof TC GemP AES_Ept
----------------------+------------------------------------------------------------------------------------------------------
v|uniport-6-1-102-1-1 | 10 Idle 10 tag inactive voip 1 256 disable
----------------------+------------------------------------------------------------------------------------------------------