Users Manual Part 2
Chapter 34 Log Setting
EMG6726/8726-B10A User’s Guide
262
The following table describes the fields in this screen.
34.2.1 Example E-mail Log
An "End of Log" message displays for each mail in which a complete log has been sent. The following is
an example of a log sent by e-mail.
• You may edit the subject title.
• The date format here is Day-Month-Year.
• The date format here is Month-Day-Year. The time format is Hour-Minute-Second.
•"End of Log" message shows that a complete log has been sent.
Table 126 Maintenance > Logs Setting
LABEL DESCRIPTION
Syslog Setting
Syslog Logging The EMG sends a log to an external syslog server. Select Enable to enable syslog logging.
Mode Select the syslog destination from the drop-down list box.
If you select Remote, the log(s) will be sent to a remote syslog server. If you select Local File, the
log(s) will be saved in a local file. If you want to send the log(s) to a remote syslog server and
save it in a local file, select Local File and Remote.
Syslog Server Enter the server name or IP address of the syslog server that will log the selected categories of
logs.
UDP Port Enter the port number used by the syslog server.
E-mail Log Settings
E-mail Log
Settings
Select Enable to have the EMG send logs and alarm messages to the configured e-mail
addresses.
Mail Account This section is available only when you select Enable in the E-mail Log Settings field.
Select a mail account from which you want to send logs. You can configure mail accounts in
the Maintenance > Email Notification screen.
System Log Mail
Subject
Type a title that you want to be in the subject line of the system log e-mail message that the
EMG sends.
Security Log
Mail Subject
Type a title that you want to be in the subject line of the security log e-mail message that the
EMG sends.
Send Log to The EMG sends logs to the e-mail address specified in this field. If this field is left blank, the EMG
does not send logs via E-mail.
Send Alarm to Alerts are real-time notifications that are sent as soon as an event, such as a DoS attack, system
error, or forbidden web access attempt occurs. Enter the E-mail address where the alert
messages will be sent. Alerts include system errors, attacks and attempted access to blocked
web sites. If this field is left blank, alert messages will not be sent via E-mail.
Alarm Interval Specify how often the alarm should be updated.
Active Log
System Log Select the categories of system logs that you want to record.
Security Log Select the categories of security logs that you want to record.
Apply Click Apply to save your changes.
Cancel Click Cancel to restore your previously saved settings.