IOTA Battery Charger, 3 Stage Smart Controller

IQ-4

Categories

Description

Description The IQ4 Charge Controller allows the DLS Series battery charger to operate as an automatic 4-Stage "Smart Charger," delivering the charge your battery needs at the time it needs it. The IQ4 uses four different charging modes to keep your battery in peak condition... Product Specifications | Download Installation | Download Warranty | Download BULK STAGE The Bulk Stage of the IQ4 allows the batteries to be charged from the full rated output of the charger (for example, a 12V charger will charge at a maximum of 14.8V). This increased charging period reduces the overall charging time of the battery. ABSORPTION STAGE After the Bulk Stage, the IQ4 then moves to the Absorption Stage (14.2V for a 12V battery). This mode will continue for up to 480 minutes (8 hours) to ensure that the battery receives a complete charge. FLOAT STAGE During the Float Stage, the IQ4 reduces the DLS charge voltage. This reduced voltage maintains the full charge while minimizing 'gassing' of the battery. The IQ4's float sta...

Manuals

#TitleLanguagesPagesUpdated
1InstallationEN22022-12-18
2Product SpecificationsEN22022-12-18