mxstm -l [-p snmp|dmi] [-f filespec ]
Description
mxstm allows you to add, remove, and list system type manager rules for use with HP SIM.
Options
-a
Add a new rule. Optionally, use -f to import one or more rules from an XML file. The XML
file must be encoded in UTF-8 and must be declared with encoding="UTF-8".
-r
Remove an existing rule. Optionally, use -f to delete one or more rules from an XML file.
The XML file must be encoded in UTF-8 and must be declared with encoding="UTF-8"
-l
List system type manager rules.
Use -n to provide a product name and list rule details.
Use the -f option to output rules to an XML file. The XML file is encoded in UTF-8.
Optionally, specify a protocol to selectively output rules matching that protocol. The
XML file output by this command is valid input for -a and -r.
-x attribute=value
Enter the name of a protocol-specific attribute and the value to assign to the attribute.
-n
Enter a product name.
-p
Enter a protocol. This value should be SNMP (SNMP or DMI if the CMS is a Microsoft
Windows system).
The SNMP required attributes are: sysoid.
The SNMP optional attributes are: url, urldesc, type, subtype, osname, osvendor, osversion, sysoidrule, oid,
oidval, oidrule, and priority.
The DMI required attributes are: comp1, group1, sgroup1, attrib1, val1, and rule1.
The DMI optional attributes are: url, type, subtype, comp2, group2, sgroup2, attrib2, val2, rule2, comp3,
group3, sgroup3, attrib3, val3, rule3, and priority.
The
type
attribute can use the values: Application, Cluster, Complex, Desktop, Enclosure, Env, Handheld,
Hub, KVM, MgmtProc, Other, PDU, Partition, Portable, PowerSupply, Printer, RAS, Rack, RESPAR, Router,
Server, SRC, Storage, Switch, TapeLibrary, UPS, Unknown, Workstation, or other values as defined in the
nodeTypesEnum table.
The
subtype
attribute can use the values: Blade, BladeSystem, BS-BMP, BS-SMC, c-Class, Dell, e-Class,
gWLMResPar, HighAvailabilityArray, HighAvailabilityCluster, HP Serviceguard, HP9000, HP9000Superdome,
HPAlphaServer, HPAlphaStation, HPDeskpro, HPEvo, HPIntegrity, HPIntegrityServer, HPIntegrityWorkStation,
HPKayak, HPNetServer, HPNonStop, HPOmnibook, HPProLiant, HPServer, HPSGCMember, HPSuperdome,
HPUNCFG, HPVectra, HPVisualize, HPVMGuest, HPVMHost, HPWorkstation, ILO, ILO2, LO100, MP-MPS,
MP-PBE-IA, MP-SPS, MSCS, None, nPar, NSCUW7, OA, OVMS, p-Class, PowerEnc, PRMResPar, RAC,
RILOE, RILOE2, ServerEnc, SMI, Storage, StorageEssentials, TCR_PS, TruCluster, TT-RCC, VMGuest, VMHost,
vPar, vParMonitor, WLMResPar, or other values as defined in the nodeSubTypesEnum table.
The attribute values for the
type
and
subtype
attributes are case sensitive.
Compare rules: StartsWith|Contains|Match|EndsWith|AnyValue
Insufficient or invalid optional attributes are replaced with sensible defaults where possible.
80 Command descriptions