Deploying HP SIM 7.0 on MSCS clusters on MS Windows 2008 with SQL Server 2008

69
Figure 57: The HP SIM 7.x home page
Note:
Navigate to OptionsDiscovery. Select System Automatic Discovery
task and click Edit. The Edit Discovery page appears. Take a look at
the Ping inclusion ranges list box (on the left side of the right frame,
near the bottom of the screen). Note that HP SIM 7.x automatically
generates a range for each of the IP addresses the current system
has. Because one of these ranges is based on the cluster heartbeat
IP address (generally of the form 10.0.0.1), that range would not be
of any use, and you should remove it from the list in order to
prevent future confusion. Be sure to click OK.
Important:
Navigate to the OptionsProtocol SettingsWMI Mapper Proxy.
Check the Host list and ensure that the cluster virtual name is used
instead of any of the system names (delete the system name, if it is
used, and add the cluster virtual name).
8. Return to the Cluster Administrator.
9. Repeat steps 2 through 6 in the Validating the installation using the other system.