Data migration of an existing Microsoft Windows CMS to a new Insight Software 6.3 system

28
- PORT - Database server port number
- The port from the database server. Default value is 1433.
- INSTANCE - Database instance
o The name of the database instance containing the IO database.
- USERNAME - Database username
o Username to be used to connect to the database.
- PASSWORD - Database password
o Username password
o On successful execution of the script , the following message will be displayed:
Sysprep references fixed.Fixing sysprep references.
o In case the fix is not necessary or already executed the following message will be
displayed:
No conversion is needed because sysprep path did not change.
o In case of failures during execution, the following message will be displayed:
Failure retrieving items from the IO database table 'LogicalSoftware'.
In this case, review the script log file (named.log) that is generated in the
directory from where the script is executed.
Step 8: Restarting the Insight Software services on the target CMS
Note:
If HP Insight Orchestration uses a remote HP Operation Orchestration server then
ensure the remote HP Operation Orchestration server property values are correct.
Follow the below steps,
In the target CMS, open Windows Explorer
Navigate to <IO Install Path>\conf
Open hpio.properties file and make sure the following lines contains the
correct values,
oo.host=<IP Address of the remote HP Operation Orchestration server>.
oo.port=<port of the remote HP Operation Orchestration server>
oo.username=<HP Operation Orchestration username>.
If the target CMS is a Cluster CMS, use Failover Cluster Manager to bring the Insight Software cluster
application online. Otherwise, start all services using the Partner Services Tool as shown in the following
example.
Usage
1. Sign in to the source CMS with operating system-level administrative privileges. Be sure this is the
same user who installed the Insight Software.
2. Open a command prompt:
a. Navigate to Start menuRun.
b. Type cmd, and then click OK. The command prompt window appears.
3. In the command prompt window, go to the Systems Insight Manager directory and execute the
partnerservice:
partnerservice start all
See Appendix D: Partner Services Tool.
Start the services in the order listed in Table 9.