HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

DescriptionAttribute
Combination of data drives and parity drives in a RAID configuration.
For P9500, if the pool is a THP pool, this item is output in the format xD+yP or
xD+xD.
xD: Number of data drives
yP: Number of parity drives
Unknown is output if the combination is unknown.
Unknown is output if any of the following conditions are satisfied:
The combinations of data drives and parity drives are unknown
The combinations of data drives and parity drives are mixed
RAID levels are mixed
A space is output for other cases.
combination
Currently, this information does not apply to storage systems (-1 is output).volAlertNotice
Over-provisioning percent (%)
If the storage system is P9500 or XP24000/XP20000 and poolFunction is 5,
the ratio of the total size of all THP volumes compared to the THP pool size is
output.
This value is output as a whole number.
This information is invalid for other cases (-1 is output).
overProvisioningPer-
cent
Over provisioning warning threshold (%)
If the storage system is P9500 or XP24000/XP20000 and poolFunction is 5,
the threshold used to issue an advance warning for the over-provisioning percent
is output.
This information is invalid for other cases (-1 is output).
overProvisioning-
Warning
Over provisioning limit threshold (%)
If the storage system is P9500 or XP24000/XP20000 and poolFunction is 5,
the threshold used to report an excess limit for the over-provisioning percent is
output.
This information is invalid for other cases (-1 is output).
overProvisioningLim-
it
Drive revolutions per minute
If the storage system is P9500 and a THP pool is used, the rotational speed (RPM)
is output.
-1 is output if any of the following conditions are satisfied:
The drive speed is unknown
Drives with different drive speeds are mixed
Drive types are mixed
This information is invalid for other cases (-1 is output).
rpm
Output items350