HP P9000 Command View Advanced Edition Suite Software 7.2 CLI Reference Guide

DescriptionStatusParameter name
Port number of the path
Specify either port or portname. Do not specify both
parameters at the same time. If they are specified at the same
time, an error will occur.
Optional
port
Port name of the path
Specify either port or portname. Do not specify both
parameters at the same time. If they are specified at the same
time, an error will occur.
Optional
portname
Domain ID of the host storage domain to which the path belongs
This parameter can be specified in decimal and hexadecimal. If
you specify a hexadecimal number, add the 0x prefix.
The execution results are output in decimal.
Either the domain or domainnickname parameter must be
specified. Do not specify both parameters at the same time. If
they are specified at the same time, an error will occur.
Optional
domain
Nickname of the host storage domain to which the path belongs
Either the domain or domainnickname parameter must be
specified. Do not specify both parameters at the same time. If
they are specified at the same time, an error will occur.
Optional
domainnickname
Device number used to identify the path
This parameter can be specified in decimal, and in
colon-separated hexadecimal. If you specify a hexadecimal
number, for XP12000/XP10000/SVS200 or XP1024/XP128,
use the xx:yy format, where xx is the CU number, and yy is
the LDEV number. For P9500 or XP24000/XP20000, use the
ww:xx:yy format, where ww is the LDKC number, xx is the CU
number, and yy is the LDEV number. ww is optional. If you omit
ww, the LDKC number is regarded as 0.
The execution results are output in decimal.
Required
devnum
For this parameter, you can specify only lusekeep.
If this parameter is omitted, a LUSE is deleted. If you do not want
to delete a LUSE, be sure to specify this parameter.
Optional
deletionoption
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
port, domain, and devnum
Obtain these values from the execution result of the GetStorageArray (subtarget=Path)
command. Execute this command by specifying only the model and serialnum parameters,
and Path for the subtarget parameter. In the execution result of this command, the devNum,
domainID, and portID values appear under An instance of Path. Use these devNum,
domainID, and portID values to specify the devnum, domain, and port parameters respect-
ively.
Command reference224