User Manual

Command Reference
Elektronik-Systeme Lauer, MAEN976 101
6.53 LAU_CONFIG_GETBRTRANGEDELTAM
(0x0122)
Backlight Level Down Range
By default, the backlight level of a Lauer Navigation Monitor can be changed within
the full range of 0 to 255 steps by using the front panel keys. To allow the backlight
level change within a limited range, a delta value can be defined. The delta value sets
the upper and lower backlight level range limits relative to the ECDIS backlight value
(which is set by the SCOM command “BRT”). Normally, upper and lower range
limits are defined as 255 for full range support. The value returned by this command
is the lower range limit relative to the ECDIS backlight level.
Supported since Firmware Version
MT223 NAV-230G: 1.0
MT226 NAV-230G: 1.0-DSCALE2
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x22 ICHKD
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0...255
Type: Byte
Length: 1
Description: Lower backlight level range limit relative to the ECDIS
backlight level