Command Line Reference Guide

show environment
View S5000 system component status (for example, temperature or voltage).
S5000
Syntax
show environment [all | fan | stack-unit unit-number | pem]
Parameters
all Enter the keyword all to view all components.
fan Enter the keyword fan to view only information on fans. The output
of this command is chassis dependent.
stack-unit
unit-
number
Enter the keyword stack-unit followed by a number to view only
information on a stack-unit. The range is 0 to 11.
pem Enter the keyword pem to view only information on power entry
modules.
Command Modes
EXEC
EXEC Privildge
Command History
Version 9.0(1.3) Introduced on the S5000.
Usage
Information
The example below shows the output of the show environment all command. You can
also display status for individual components.
Example (all)
FTOS#show environment all
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed Fan2
Speed Fan3 Speed
---------------------------------------------------------------
-----------------------
1 1 up up 12000 up 12000 up
12000 up 12000
1 2 up up 12000 up 12000 up
12000 up 12000
Speed in RPM
-- Power Supplies --
Unit Bay Status Type FanStatus
---------------------------------------------------------------
-------------
1 0 up AC up
1 3 up AC up
-- Thermal Sensor Readings (degree C) --
-- Unit 1 --
S0 S1 S2 S3 S4 S5 S6 S7
---------------------------------------------------------------
---------------------------------------
BASE BOARD 40 33 29 33 31 49 33 43
Module 0 31 35 34 - - - - -
110